Background
Hemodynamic response to intra-aortic balloon pump (IABP) therapy is highly heterogeneous, and predictors of response remain poorly defined. To date, no studies have evaluated the role of right ventricular-pulmonary artery (RV-PA) coupling, a key determinant of RV energetic efficiency, in modulating response to IABP support. Hypothesis: Baseline (before IABP implant) RV-PA coupling is associated with cardiac index (CI), mean arterial pressure (MAP), and wedge pressure following IABP support.
Methods
We performed a longitudinal analysis using mixed-effects modeling to evaluate the association between baseline RV-PA coupling (ratio of RV end-systolic elastance [Ees], reflecting contractility, to PA elastance [Ea], reflecting afterload) and CI (by Fick method), MAP, and wedge pressure during IABP support. Ees/Ea was estimated using a single-beat method derived from invasive pressure waveforms obtained during right heart catheterization prior to IABP insertion. The models included fixed effects for baseline Ees/Ea, IABP support, and time from IABP initiation, with random intercepts at the patient level. A maximum of 102 observations from 31 patients were analyzed (mean 3.3 observations per patient).
Results
31 cardiogenic shock patients (baseline demographics in the Table) were included. Baseline RV-PA coupling was independently associated with higher CI during IABP support (β=0.60, SE=0.25, p=0.016, 95% CI 0.11-1.08). IABP support was associated with a significant increase in CI (β=0.58, SE=0.17, p
Zitieren
APA
Gidon, A., Saeed, O., Jorde, U. P., & Castagna, F. (2026). Abstract 5328: Right Ventricular-Pulmonary Arterial Coupling is Associated with Cardiac Index During Intra-Aortic Balloon Pump Support. Circulation, 154(Suppl_1). https://doi.org/10.1161/circ.154.suppl_1.5328
Vancouver
Gidon A, Saeed O, Jorde UP, Castagna F. Abstract 5328: Right Ventricular-Pulmonary Arterial Coupling is Associated with Cardiac Index During Intra-Aortic Balloon Pump Support. Circulation. 2026;154(Suppl_1). doi:10.1161/circ.154.suppl_1.5328
BibTeX
@article{Gidon2026,
author = {Gidon, Ariel and Saeed, Omar and Jorde, Ulrich P and Castagna, Francesco},
title = {Abstract 5328: Right Ventricular-Pulmonary Arterial Coupling is Associated with Cardiac Index During Intra-Aortic Balloon Pump Support},
journal = {Circulation},
year = {2026},
volume = {154},
number = {Suppl_1},
doi = {10.1161/circ.154.suppl_1.5328}
}
EUVIMED