An analysis of preanalytical errors in the Biochemistry Unit of the National Referral Hospital in Bhutan: A descriptive study
Bhutan Health Journal · 2026-07-29 · 12 (2) · 6
DOI: 10.47811/216 ↗At a glance
Journal article in Bhutan Health Journal, published online on 2026-07-29. Written by Sonam ChhodenR and 2 co-authors. The full text is freely available (open access, CC BY 4.0).
Abstract (original language)
Introduction
Accurate and timely reporting of laboratory results is essential for optimal patient management. The testing process in clinical biochemistry is divided into pre-analytical, analytical, and post-analytical phases. This study assessed the sample rejection rate and identified common pre-analytical errors in the Biochemistry Unit of Jigme Dorji Wangchuck National Referral Hospital.
Methods
A retrospective observational study was conducted by reviewing records of all rejected samples in the Biochemistry Unit from January 2019 to December 2020.
Results
Of 197,735 samples received for biochemical testing, 283 were rejected, giving an overall sample rejection rate of 0.14%. The most common reasons for rejection were insufficient sample volume (51%) and hemolysed samples (28%). The neonatal intensive care unit contributed the highest proportion of rejected samples (32%), followed by inpatient wards (25%) and the emergency department (17%).
Conclusion
The sample rejection rate in the Biochemistry Unit was low at 0.14%, with insufficient sample volume being the leading cause of rejection. Targeted training in neonatal blood collection, adherence to standardized collection protocols, and the use of micro-collection tubes may help mitigate pre-analytical errors and improve sample adequacy.
Cite
APA
ChhodenR, S., Jamtsho, S., & Wangmo, N. (2026). An analysis of preanalytical errors in the Biochemistry Unit of the National Referral Hospital in Bhutan: A descriptive study. Bhutan Health Journal, 12(2), 6. https://doi.org/10.47811/216
Vancouver
ChhodenR S, Jamtsho S, Wangmo N. An analysis of preanalytical errors in the Biochemistry Unit of the National Referral Hospital in Bhutan: A descriptive study. Bhutan Health Journal. 2026;12(2):6. doi:10.47811/216
BibTeX
@article{ChhodenR2026,
author = {ChhodenR, Sonam and Jamtsho, Sonam and Wangmo, Nezang},
title = {An analysis of preanalytical errors in the Biochemistry Unit of the National Referral Hospital in Bhutan: A descriptive study},
journal = {Bhutan Health Journal},
year = {2026},
volume = {12},
number = {2},
pages = {6},
doi = {10.47811/216}
}