EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Transcatheter Closure of Patent Ductus Arteriosus in Infants: A Retrospective Single-Center Study of Procedural Feasibility, Success, and Early Outcomes

Qudsia Riaz, Abdul Malik Sheikh, Asma Kanwal, Kiran Azim, Malik Abid Ali, Faiza Fayyaz

Pakistan Heart Journal · 11.10.2026 · 59 (5) · 1636-1644

DOI: 10.47144/phj.v59i5.3364 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pakistan Heart Journal, online erschienen am 11.10.2026. Verfasst von Qudsia Riaz und 5 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Patent ductus arteriosus (PDA) is one of the most common congenital heart defects encountered during infancy and may lead to significant hemodynamic compromise if left untreated. Transcatheter closure has increasingly become the preferred treatment modality; however, data regarding procedural outcomes in infants from developing countries remain limited. This study aimed to evaluate the feasibility, procedural success, and short-term outcomes of transcatheter PDA device closure in infants at a tertiary cardiac center. Methodology: This retrospective descriptive study was conducted at the Pediatric Cardiology Department of Rawalpindi Institute of Cardiology, Pakistan. Medical records of infants younger than one year who underwent evaluation for transcatheter PDA closure reviewed. Demographic characteristics, echocardiographic findings, procedural details, device types, procedural success, and early complications were extracted and analyzed. PDA diagnosis and assessment of hemodynamic significance were established using transthoracic echocardiography. All procedures were performed under general anesthesia using fluoroscopic and echocardiographic guidance. Short-term outcomes and complications were assessed during hospitalization and before discharge.

Results

A total of 247 infants were evaluated for transcatheter PDA closure. Following angiographic assessment, device closure was not performed in 8 (3.2%) patients because of unfavorable ductal anatomy. Among the remaining 239 infants, successful device closure was achieved in 238 patients, resulting in a procedural success rate of 99.6%. There were 92 (38.5%) males and 147 (61.5%) females. The mean age was 11.0 ± 2.0 months, while the mean body weight was 7.8 ± 1.8 kg. Conventional PDA occluders were used in the majority of patients. One patient (0.4%) experienced device embolization requiring successful percutaneous retrieval and was classified as a major complication. Minor complications occurred in 5 (2.1%) patients and resolved without surgical intervention or residual morbidity.

Conclusion

Transcatheter PDA closure in infants demonstrated excellent procedural success and a low frequency of early complications. The findings support the feasibility of this minimally invasive approach in appropriately selected infants when performed in experienced centers.

Zitieren

APA

Riaz, Q., Sheikh, A. M., Kanwal, A., Azim, K., Ali, M. A., & Fayyaz, F. (2026). Transcatheter Closure of Patent Ductus Arteriosus in Infants: A Retrospective Single-Center Study of Procedural Feasibility, Success, and Early Outcomes. Pakistan Heart Journal, 59(5), 1636-1644. https://doi.org/10.47144/phj.v59i5.3364

Vancouver

Riaz Q, Sheikh AM, Kanwal A, Azim K, Ali MA, Fayyaz F. Transcatheter Closure of Patent Ductus Arteriosus in Infants: A Retrospective Single-Center Study of Procedural Feasibility, Success, and Early Outcomes. Pakistan Heart Journal. 2026;59(5):1636-1644. doi:10.47144/phj.v59i5.3364

BibTeX
@article{Riaz2026,
  author = {Riaz, Qudsia and Sheikh, Abdul Malik and Kanwal, Asma and Azim, Kiran and Ali, Malik Abid and Fayyaz, Faiza},
  title = {Transcatheter Closure of Patent Ductus Arteriosus in Infants: A Retrospective Single-Center Study of Procedural Feasibility, Success, and Early Outcomes},
  journal = {Pakistan Heart Journal},
  year = {2026},
  volume = {59},
  number = {5},
  pages = {1636--1644},
  doi = {10.47144/phj.v59i5.3364}
}
Kostenlos starten →