EUVIMEDEUVIMED entdecken
Crossref

Prototype of Electromagnetic-Based Aerator Pump Automatic Control System

Erwin Erwin, Siti Nursakila

Advances In Social Humanities Research · 23.11.2026 · 4 (11) · 2156-2174

DOI: 10.46799/adv.v4i11.788 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Advances In Social Humanities Research, online erschienen am 23.11.2026. Verfasst von Erwin Erwin und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Water quality, particularly dissolved oxygen (DO) concentration, is a critical factor in the success of intensive aquaculture systems. Aerator pumps are commonly used to maintain adequate DO concentrations; however, their operation often relies on manual control or continuous operation, potentially resulting in excessive electrical energy consumption and accelerated equipment wear. Digital electronic control systems based on microcontrollers, such as Arduino, and Internet of Things (IoT) technologies offer advanced automation capabilities but may require additional protection to ensure reliability in aquaculture environments characterized by high humidity, temperature fluctuations, and exposure to water splashes. This study aimed to design, assemble, and evaluate a prototype automatic control system using electromechanical switching components for a 350 W, 220 V AC aerator pump. The research involved a literature review, field observations, component layout design, preparation of equipment and materials, prototype assembly, and functional testing. The system incorporated a Schneider Electric 2 A miniature circuit breaker (MCB), two Theben SUL 181 h time switches, CHINT NXC-09 electromagnetic contactors, and a CHINT NXR-25 thermal overload relay (TOR), with component selection based on a calculated operating current of 1.98 A. Functional testing demonstrated that the components operated successfully as an integrated control system. The aerator pump automatically switched on and off according to the programmed operating schedule of 07:00–18:00, maintained stable operation during testing, and eliminated the need for routine manual switching. The MCB tripped within approximately 3 seconds under a 900 W test load, while the thermal overload relay's auxiliary contacts responded as intended during overload testing. The findings indicated that electromechanical timer-based switching systems, similar to those used in public street lighting (Penerangan Jalan Umum, PJU), could be adapted to control inductive loads such as aerator pumps, providing a relatively simple and maintainable automation solution for aquaculture operations. However, the system operated according to a fixed schedule and could not automatically adjust aeration based on environmental conditions or real-time DO concentrations. Further research is therefore recommended to integrate DO sensors and conduct long-term reliability assessments and quantitative evaluations of electrical energy savings.

Zitieren

APA

Erwin, E., & Nursakila, S. (2026). Prototype of Electromagnetic-Based Aerator Pump Automatic Control System. Advances In Social Humanities Research, 4(11), 2156-2174. https://doi.org/10.46799/adv.v4i11.788

Vancouver

Erwin E, Nursakila S. Prototype of Electromagnetic-Based Aerator Pump Automatic Control System. Advances In Social Humanities Research. 2026;4(11):2156-2174. doi:10.46799/adv.v4i11.788

BibTeX
@article{Erwin2026,
  author = {Erwin, Erwin and Nursakila, Siti},
  title = {Prototype of Electromagnetic-Based Aerator Pump Automatic Control System},
  journal = {Advances In Social Humanities Research},
  year = {2026},
  volume = {4},
  number = {11},
  pages = {2156--2174},
  doi = {10.46799/adv.v4i11.788}
}
Kostenlos starten →