EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Inter Rater Reliability Test of Digitalized Telescoping Goniometer to Measure Active Range of Motion of Selected Large Joints Among Healthy Individuals

Nadine Aguilar, Neil Alamillo, John Ambag, Raiviel Ambrocio, Jessa Buenagua, Pamela Caguiat, Er. D. Petil, Kenneth Charles Mutia

Philippine Journal of Physical Therapy · 2022

DOI: 10.46409/002.aght4732 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Philippine Journal of Physical Therapy, 2022. Verfasst von Nadine Aguilar und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

This study aimed to create an alternative tool for joint measurements with higher level of confidence and minimal error.

Methods

This was a quantitative exploratory research study that determines the inter-rater reliability of the Digitalized telescoping Goniometer (DTG). 25 healthy individuals were selected using Slovin’s Formula. SPSS version 24 was used in analyzing the reliability and validity. The inter- rater reliability is described by Intra class coefficient (ICC) and Limits of Agreement (LOA). The references for the interpretation of the ICC in the present study were poor reliability < 0.5, moderate reliability 0.5-0.75 good reliability 0.75-0.90, and excellent reliability for > 0.90. The Bland-Altman plots was used to investigate systematic differences and assess 95% limits of agreement (LOA) visual indication of agreement. In LOA is calculated as LOA = mean difference + 1.96 (SD).

Results

The ICC result of the DGT had moderate to good reliability for shoulder, elbow and hip joint (0.8835, 0.7395, 0.66525) respectively, while poor reliability on the knee joint (0.48175). The SEM taken using DGT ranged from 1.40- 7.27. The result showed moderate reliability on shoulder (0.7055), elbow (0.5215) and knee joint (0.576) while the hip joint (0.4825) showed poor reliability. As for the LOA, DTG has a wider limit than universal goniometer for all ROM. Conclusion and Implication: DGT showed as a reliable tool in measuring the ROM. DTG is a device can be use in goniometry.

Zitieren

APA

Aguilar, N., Alamillo, N., Ambag, J., Ambrocio, R., Buenagua, J., Caguiat, P., Petil, E. D., & Mutia, K. C. (2022). Inter Rater Reliability Test of Digitalized Telescoping Goniometer to Measure Active Range of Motion of Selected Large Joints Among Healthy Individuals. Philippine Journal of Physical Therapy. https://doi.org/10.46409/002.aght4732

Vancouver

Aguilar N, Alamillo N, Ambag J, Ambrocio R, Buenagua J, Caguiat P, et al. Inter Rater Reliability Test of Digitalized Telescoping Goniometer to Measure Active Range of Motion of Selected Large Joints Among Healthy Individuals. Philippine Journal of Physical Therapy. 2022. doi:10.46409/002.aght4732

BibTeX
@article{Aguilar2022,
  author = {Aguilar, Nadine and Alamillo, Neil and Ambag, John and Ambrocio, Raiviel and Buenagua, Jessa and Caguiat, Pamela and Petil, Er. D. and Mutia, Kenneth Charles},
  title = {Inter Rater Reliability Test of Digitalized Telescoping Goniometer to Measure Active Range of Motion of Selected Large Joints Among Healthy Individuals},
  journal = {Philippine Journal of Physical Therapy},
  year = {2022},
  doi = {10.46409/002.aght4732}
}
Kostenlos starten →