Transient stability analysis with equal-area criterion for out of step detection using phasor measurement units
International Journal of Engineering, Science and Technology · 28.03.2018 · 5 (1) · 1-17
DOI: 10.4314/ijest.v5i1.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Engineering, Science and Technology, online erschienen am 28.03.2018. Verfasst von A.Y. Abdelaziz und 2 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
The electrical power systems function as a huge interconnected network dispersed over a large area. A balance exist between generated and consumed power, any disturbance to this balance in the system caused due to change in load as well as faults and their clearance often results in electromechanical oscillations. As a result there is variation in power flow between two areas. This phenomenon is referred as Power Swing. This paper presents a transmission line protection scheme that uses measured values of the currents and voltages of the three phases of two buses (equivalent to PMU data). The measured data is transformed from time domain into phasor domain using Discrete Fourier Transform to predict whether the swing is a stable or an unstable one. The performance of the method has been tested on a simulated system using PSCAD and MATLAB software. The proposed scheme can be used for the detection of out of step condition using equal-area criterion with different types of faults at different locations and different models of transmission lines.Keywords: Phasor Measurement Unit, Global positioning system, Transmission line protection, Power system transient stability, Discrete Fourier Transform, Equal-Area Criterion, Out of step detection
Zitieren
APA
Abdelaziz, A., Ibrahim, A. M., & Hasan, Z. G. (2018). Transient stability analysis with equal-area criterion for out of step detection using phasor measurement units. International Journal of Engineering, Science and Technology, 5(1), 1-17. https://doi.org/10.4314/ijest.v5i1.1
Vancouver
Abdelaziz A, Ibrahim AM, Hasan ZG. Transient stability analysis with equal-area criterion for out of step detection using phasor measurement units. International Journal of Engineering, Science and Technology. 2018;5(1):1-17. doi:10.4314/ijest.v5i1.1
BibTeX
@article{Abdelaziz2018,
author = {Abdelaziz, A.Y. and Ibrahim, Amr M. and Hasan, Zeinab G.},
title = {Transient stability analysis with equal-area criterion for out of step detection using phasor measurement units},
journal = {International Journal of Engineering, Science and Technology},
year = {2018},
volume = {5},
number = {1},
pages = {1--17},
doi = {10.4314/ijest.v5i1.1}
}
EUVIMED