Power system stability enhancement utilizing phasor measurement units at transient and steady state
Mansoura Engineering Journal · 01.01.2023 · 48 (3)
DOI: 10.58491/2735-4202.3031 ↗Kurz gefasst
Fachartikel in der Zeitschrift Mansoura Engineering Journal, online erschienen am 01.01.2023. Verfasst von Moamen M. Mousa und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Abstract—Efficient power system stability monitoring plays a vital role in recent electric grid technologies. It supports operators at control centers to reduce overloading on weak elements and prevent power system from collapse. In this paper Phasor Measurement Units (PMUs) technology has been used for real-time measurements that can obtain fast and accurate data samples from the electric network. The system stability responses during steady state and transient conditions have been studied based on the data driven from PMUs. The proposed study has been applied on WSCC 9-bus system. Test system Simulink has been modified to include the required PMUs and other necessary measuring devices. Trusted six voltage stability indices have been estimated. Consequently, the lines and buses have been ranked as per its weakness and the voltage stability margin became clear to control center operators. The main objective of this paper is to use these indices as an efficient awareness tool to the operator and aims to avoid collapse and to support in taking necessary remedial actions such as installing FACTS. In addition, Three Power System Stabilizers (PSSs) effect on the network voltage stability, rotor angle stability and frequency stability has been carried out; As a result, MB-PSS is found as the most reliable one. By investigating the generators response, the fault location has been predicted. It has been approved from analysis to the results that MB-PSS shorten the stability recovery time from 6 sec to 2 sec and keep voltage within limits during fault condition for longer time. MATLAB Simpower System toolbox has been used for load flow, transient, and steady state stability analysis.
Zitieren
APA
Mousa, M. M., Kandel, M. S., Kadah, S. S., & Kotb, M. F. (2023). Power system stability enhancement utilizing phasor measurement units at transient and steady state. Mansoura Engineering Journal, 48(3). https://doi.org/10.58491/2735-4202.3031
Vancouver
Mousa MM, Kandel MS, Kadah SS, Kotb MF. Power system stability enhancement utilizing phasor measurement units at transient and steady state. Mansoura Engineering Journal. 2023;48(3). doi:10.58491/2735-4202.3031
BibTeX
@article{Mousa2023,
author = {Mousa, Moamen M. and Kandel, Mahmoud S. and Kadah, Sahar S. and Kotb, Mohamed F.},
title = {Power system stability enhancement utilizing phasor measurement units at transient and steady state},
journal = {Mansoura Engineering Journal},
year = {2023},
volume = {48},
number = {3},
doi = {10.58491/2735-4202.3031}
}
EUVIMED