Evaluating the relationship between size-specific dose estimates and effective dose in abdominal computed tomography examinations: a single Centre study
Global Journal of Pure and Applied Sciences · 2026 · 32 (4) · 561-569
DOI: 10.4314/gjpas.v32i4.7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Global Journal of Pure and Applied Sciences, 2026. Verfasst von Emmanuel O. Esien-Umo und 6 weiteren Autor:innen.
Abstract (Originalsprache)
The volume computed tomography index (CTDIvol) displayed in the dose report of computed tomography (CT) examinations does not represent the actual patient dose, due to its insensitivity to varying patient size. However, it serves as the baseline output for calculating size-specific dose estimates (SSDE), which accounts for the actual patient dose, and effective dose (ED), which estimates the overall risk from the radiation exposure.
Aim
Given the limitations of CTDIvol, the present study aims to evaluate the relationship between SSDE (patient dose) and ED (biological risk) and to assess the deviation between both dose metrics.
Method
Data were extracted from the dose reports of CT images of 54 adult patients referred for abdominopelvic examinations at a Private Diagnostic Centre in Port Harcourt, Rivers State, Nigeria. Information such as the 120 kVp, 79–359 mAs, 5 mm slice thickness and interval, CTDIvol, dose-length product (DLP) and scan length was obtained from a 64-slice CT machine with automatic exposure control (AEC) modulation. The effective diameter (Deff) was calculated from the measured lateral and anterior-posterior diameters. This value was used to determine the SSDE. Furthermore, the product of DLP and tissue weighting factor yielded the ED. Regression analysis was used to develop models for SSDE, CTDIvol, and ED, while Pearson’s correlation and percentage difference were used to show the relationship and deviation between SSDE and ED.
Results
Results showed that the SSDE and CTDIvol achieved unity at 32 cm Deff. The percentage difference between SSDE and ED reduced significantly from 42% to 0.86% as patient size increased. All dose metrics increased with increasing Deff and the Pearson’s correlation between SSDE and ED was significantly strong (r=0.982, p=0.001).
Conclusion
This study shows that the ED provides a good estimate of the biological risk for larger sized patients compared with smaller sized patients in abdomin-pelvic CT examinations.
Zitieren
APA
Esien-Umo, E. O., Egong, A. E., Ishiekwen, C. A., David, S. E., Effiong, G. M., Mark, G. A., & Egbe, N. O. (2026). Evaluating the relationship between size-specific dose estimates and effective dose in abdominal computed tomography examinations: a single Centre study. Global Journal of Pure and Applied Sciences, 32(4), 561-569. https://doi.org/10.4314/gjpas.v32i4.7
Vancouver
Esien-Umo EO, Egong AE, Ishiekwen CA, David SE, Effiong GM, Mark GA, et al. Evaluating the relationship between size-specific dose estimates and effective dose in abdominal computed tomography examinations: a single Centre study. Global Journal of Pure and Applied Sciences. 2026;32(4):561-569. doi:10.4314/gjpas.v32i4.7
BibTeX
@article{EsienUmo2026,
author = {Esien-Umo, Emmanuel O. and Egong, Akpama Egwu and Ishiekwen, Christopher A. and David, Solomon E. and Effiong, Godswill M. and Mark, Glory Anthony and Egbe, Nneoyi O.},
title = {Evaluating the relationship between size-specific dose estimates and effective dose in abdominal computed tomography examinations: a single Centre study},
journal = {Global Journal of Pure and Applied Sciences},
year = {2026},
volume = {32},
number = {4},
pages = {561--569},
doi = {10.4314/gjpas.v32i4.7}
}
EUVIMED