EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Radiation Dose Evaluation in Pediatric Patients Undergoing Repeated Brain Computed Tomography Examinations

Mohammad Aljamal iD, Noor Abuasbi, Awadia Gareeballah iD, Zuhal Y Hamd iD, Mohammed Alharbi, Amna M Ahmed iD, Lama Almudaimeegh iD, Areej Hamami iD

Diagnostics · 23.04.2026 · 16 (9) · 1265

DOI: 10.3390/diagnostics16091265 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostics, online erschienen am 23.04.2026. Verfasst von Mohammad Aljamal und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging, Faculty of Allied Medical Sciences, Arab American University, 13 Zababdeh, Jenin P.O. Box 240, Palestine. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Repeated brain computed tomography (CT) scans in children may result in substantial cumulative radiation exposure, particularly in young children, who are more sensitive to ionizing radiation. The purpose of the study was to assess the dose levels of radiation in patients who receive repeated brain CT during childhood and adherence rates to pediatric imaging protocols.

Methods

A retrospective cross-sectional study was conducted among 177 patients aged ≤5 years who underwent two or more brain CT examinations with a total of 514 CT examinations. The information was gathered through the hospital Picture Archiving and Communication System (PACS), which included patient demographics, scan parameters, and scanner-reported dose indicators such as volume-averaged computed tomography dose index (CTDIvol) and dose-length product (DLP). The effective dose (ED) was calculated and compared with estimated doses based on a nominal pediatric CT protocol.

Results

The findings indicated a great variation in scan parameters, with CTDIvol values of 8.9 to 51.7 mGy and DLP values of 177 to 1310 mGy.cm. The number of repeated scans showed a great increase in the cumulative ED (p < 0.001). The median doses in patients below the age of one year were greater than those in older children. There was also a closer relation of scanner-reported doses to adult protocols, which suggests a lack of an optimized pediatric setting.

Conclusions

Children under 5 who undergo repeated brain CT scans may face excessive radiation exposure. The matter is aggravated by the fact that scans are performed repeatedly without optimization of the dose, which leads to significant cumulative ED.

Schlagwörter

Stichwörter der Autor:innen

ALARACTDIvolDLPeffective dosepediatric brain CTprotocol optimizationradiation doserepeated scans

Autor:innen und Institutionen

  • Department of Medical Imaging, Faculty of Allied Medical Sciences, Arab American University, 13 Zababdeh, Jenin P.O. Box 240, Palestine.
  • Department of Diagnostic Radiology, College of Applied Medical Sciences, Taibah University, Madinah 42353, Saudi Arabia.
  • Department of Radiological Sciences, College of Health and Rehabilitation Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.
  • Medical Imaging Department, King Abdullah bin Abdulaziz University Hospital, P.O. Box 47330, Riyadh 11552, Saudi Arabia.
  • Department of Radiological Sciences, College of Applied Medical Sciences, King Khalid University, P.O. Box 960, Abha 61421, Saudi Arabia.
  • Internal Medicine Department, College of Medicine, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia.

ORCID-Profile: Mohammad Aljamal, Awadia Gareeballah, Zuhal Y Hamd, Amna M Ahmed, Lama Almudaimeegh, Areej Hamami

Zitieren

APA

Aljamal, M., Abuasbi, N., Gareeballah, A., Hamd, Z. Y., Alharbi, M., Ahmed, A. M., Almudaimeegh, L., & Hamami, A. (2026). Radiation Dose Evaluation in Pediatric Patients Undergoing Repeated Brain Computed Tomography Examinations. Diagnostics, 16(9), 1265. https://doi.org/10.3390/diagnostics16091265

Vancouver

Aljamal M, Abuasbi N, Gareeballah A, Hamd ZY, Alharbi M, Ahmed AM, et al. Radiation Dose Evaluation in Pediatric Patients Undergoing Repeated Brain Computed Tomography Examinations. Diagnostics. 2026;16(9):1265. doi:10.3390/diagnostics16091265

BibTeX
@article{Aljamal2026,
  author = {Aljamal, Mohammad and Abuasbi, Noor and Gareeballah, Awadia and Hamd, Zuhal Y and Alharbi, Mohammed and Ahmed, Amna M and Almudaimeegh, Lama and Hamami, Areej},
  title = {Radiation Dose Evaluation in Pediatric Patients Undergoing Repeated Brain Computed Tomography Examinations},
  journal = {Diagnostics},
  year = {2026},
  volume = {16},
  number = {9},
  pages = {1265},
  doi = {10.3390/diagnostics16091265}
}
Kostenlos starten →