EUVIMEDEUVIMED entdecken
Open Access

Effect of Body Mass Index on Effective Dose in Multi Detector Computed Tomography Abdomen Using Automatic Exposure Control

S Shailesh Nayak, Sushil Yadav, Abhimanyu Pradhan

Ethiopian Journal of Health Sciences · 2024

DOI: 10.4314/ejhs.v34i6.9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ethiopian Journal of Health Sciences, 2024. Verfasst von S Shailesh Nayak und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, Ind…. Hauptthemen laut MEDLINE: Body Mass Index, Radiation Dosage, Obesity, Multidetector Computed Tomography. Die Arbeit wurde bisher 1-mal zitiert (Crossref). Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Computed Tomography (CT) of the abdomen is one of the most frequently performed scans in adults for various abdominal pathologies. Its popularity stems from the immediate image reconstruction following acquisition. However, CT scans are known for their high radiation doses compared to other diagnostic X-ray procedures. This study aimed to analyze the effective dose in patients with varying body habitus during multidetector CT of the abdomen using automatic exposure control. METHODS: This prospective study was conducted in the Department of Radiodiagnosis and Imaging from February 2017 to March 2018. Patients aged 18 and older, regardless of gender, undergoing routine Contrast-Enhanced CT (CECT) of the abdomen were included. Participants were categorized into three groups based on Body Mass Index (BMI): normal weight, overweight, and obese. RESULTS: A total of 168 patients were enrolled, with a mean age of 49.8 ± 15.6 years, predominantly male (66.1%). Obese individuals exhibited significantly higher effective dose values (16.57 ± 2.27 mSv) compared to normal weight (9.45 ± 0.92 mSv) and overweight individuals (11.88 ± 0.77 mSv) (p < 0.01). Similarly, obese patients had significantly higher values for Computed Tomography Dose Index Volume (CTDIvol) (18.32 ± 2.54 mGy) and Dose Length Product (DLP) (1104.86 ± 151.84 mGycm) compared to normal weight (CTDIvol: 11.38 ± 1.24 mGy; DLP: 630.55 ± 61.57 mGycm) and overweight individuals (CTDIvol: 13.56 ± 1.15 mGy; DLP: 792.37 ± 51.56 mGy*cm) (p < 0.05). CONCLUSION: The effective dose received by obese patients during abdominal CT exams with Automatic Exposure Control (AEC) is nearly double that of normal-weight patients.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body Mass IndexRadiation DosageObesityMultidetector Computed TomographyAbdomenRadiography, AbdominalHumansMaleFemaleMiddle AgedAdultProspective StudiesAgedOverweightTomography, X-Ray Computed

Stichwörter der Autor:innen

Automatic Exposure ControlBody Mass IndexComputed TomographyDose Length ProductVolumetric CT Dose IndexkVpmAs

Autor:innen und Institutionen

  • Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.
  • Department of Allied Health Sciences, Manipal Tata Medical College, Manipal Academy of Higher Education, Karnataka, Manipal, 576104, India.

Zitieren

APA

Shailesh Nayak, S., Yadav, S., & Pradhan, A. (2024). Effect of Body Mass Index on Effective Dose in Multi Detector Computed Tomography Abdomen Using Automatic Exposure Control. Ethiopian Journal of Health Sciences. https://doi.org/10.4314/ejhs.v34i6.9

Vancouver

Shailesh Nayak S, Yadav S, Pradhan A. Effect of Body Mass Index on Effective Dose in Multi Detector Computed Tomography Abdomen Using Automatic Exposure Control. Ethiopian Journal of Health Sciences. 2024. doi:10.4314/ejhs.v34i6.9

BibTeX
@article{ShaileshNayak2024,
  author = {Shailesh Nayak, S and Yadav, Sushil and Pradhan, Abhimanyu},
  title = {Effect of Body Mass Index on Effective Dose in Multi Detector Computed Tomography Abdomen Using Automatic Exposure Control},
  journal = {Ethiopian Journal of Health Sciences},
  year = {2024},
  doi = {10.4314/ejhs.v34i6.9}
}
Kostenlos starten →