EUVIMEDEUVIMED entdecken
Crossref

Exploring the correlation between effective dose and BMI-based size-specific dose estimate in CT angiography

Hariwan A Mohammed, Dindar S Bari, Haval Y Yacoob Aldosky, Edrees M Tahir

European Journal of Radiology · 2025

DOI: 10.1016/j.ejrad.2025.112342 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Hariwan A Mohammed und 3 weiteren Autor:innen. Beteiligte Einrichtung: College of Medicine, University of Duhok, Kurdistan Region, Iraq. Hauptthemen laut MEDLINE: Body Mass Index, Radiation Dosage, Computed Tomography Angiography, Coronary Angiography. Die Arbeit nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Computed tomography angiography (CTA) is a widely used diagnostic tool, but concerns about radiation exposure necessitate accurate dose estimation. This study investigates the correlation between Effective Dose (ED) and Size-Specific Dose Estimate (SSDE) estimated from the patient's body mass index (BMI) in CTA to evaluate the utility of SSDE-BMI as a patient-specific dosimetry parameter. METHODS: A retrospective analysis of 422 adult patients (226 males and 196 females) with an average age of 51.28 years undergoing Coronary Computed Tomography Angiography (CCTA) was conducted. Two values of ED were derived (ED103 and EDDLP derived using the dose-length product (DLP) and ICRP conversion factors), while the two values of SSDEBMI were calculated from the volume-computed tomography dose index (CTDIvol) and the patient's BMI. RESULTS: Overall, statistical analysis revealed a strong positive correlation between ED103 and SSDEBMIs, significantly stronger than correlations between traditional metrics EDDLP and SSDEBMI. A highly significant correlation between these two dose indices was observed across various patients' BMI and gender. The highest correlation was reported for Obese Class II female patients, which is attributed to proportional dose adjustments made to compensate for increased X-ray attenuation. CONCLUSIONS: These findings underscore SSDEs' importance in personalized radiation risk assessment and protocol optimization. This supports the use of SSDEBMI as a reliable, patient-specific dose metric in radiation protection strategies for CCTA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Body Mass IndexRadiation DosageComputed Tomography AngiographyCoronary AngiographyRadiation ExposureHumansMaleFemaleMiddle AgedRetrospective StudiesAgedAdultRadiometryReproducibility of Results

Stichwörter der Autor:innen

AngiographyBody mass indexDose-length productEffective doseSize-specific dose estimate

Autor:innen und Institutionen

  • College of Medicine, University of Duhok, Kurdistan Region, Iraq.
  • Scientific Research Center, University of Zakho, Zakho, Kurdistan Region, Iraq; Department of Physics, College of Science, University of Zakho, Zakho, Kurdistan Region, Iraq. Electronic address: dindar.bari@uoz.edu.krd.
  • Department of Physics, College of Science, University of Duhok, Kurdistan Region, Iraq.
  • Erbil Technical Engineering College, Erbil Polytechnic University, Erbil, Kurdistan Region, Iraq.

Zitieren

APA

Mohammed, H. A., Bari, D. S., Yacoob Aldosky, H. Y., & Tahir, E. M. (2025). Exploring the correlation between effective dose and BMI-based size-specific dose estimate in CT angiography. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112342

Vancouver

Mohammed HA, Bari DS, Yacoob Aldosky HY, Tahir EM. Exploring the correlation between effective dose and BMI-based size-specific dose estimate in CT angiography. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112342

BibTeX
@article{Mohammed2025,
  author = {Mohammed, Hariwan A and Bari, Dindar S and Yacoob Aldosky, Haval Y and Tahir, Edrees M},
  title = {Exploring the correlation between effective dose and BMI-based size-specific dose estimate in CT angiography},
  journal = {European Journal of Radiology},
  year = {2025},
  doi = {10.1016/j.ejrad.2025.112342}
}