Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair

Andres Fontaine-Nicola, Hayley Harman, Edgardo Reyes, Mustafa Hajjar, Nova Szoka

CRSLS : MIS Case Reports from SLS · 2026

DOI: 10.4293/crsls.2026.00069 ↗

Kurz gefasst

Fallbericht in der Zeitschrift CRSLS : MIS Case Reports from SLS, 2026. Verfasst von Andres Fontaine-Nicola und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, North Shore University Hospital, Zucker School of Medicine at Hofstra/Northwell, Manhasset, New York, USA. (Dr. Fontaine-Nicol…. Hauptthemen laut MEDLINE: Hernia, Hiatal, Robotic Surgical Procedures, Herniorrhaphy. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fluorescence-guided (FG) surgery using near-infrared imaging has been adopted to enhance intraoperative visualization in multiple surgical fields. In foregut surgery, calibration tubes are routinely used to calibrate crural closure but due to limited visibility carry a risk of iatrogenic injury, including esophageal or gastric perforation. Techniques that improve visualization of these devices may support safer intraoperative management. Case Presentation: A 75-year-old woman with a symptomatic paraesophageal hiatal hernia and partial gastric volvulus underwent robotic paraesophageal hiatal hernia repair with Toupet fundoplication. A FG gastric calibration tube (size 40 Fr, Endolumik Inc.), was inserted under near-infrared visualization and advanced down the esophagus and into the stomach. The device was used to (1) evacuate gastric contents, (2) guide tube positioning past the gastroesophageal junction, (3) inform mediastinal dissection/esophageal mobilization, (4) enable FG measuring of the length of esophageal mobilization below the diaphragm, and (5) calibrate both crural closure and fundoplication. The procedure was completed without intraoperative complications. The patient was discharged on postoperative day 1 and reported resolution of dysphagia at 8-week follow-up.

Discussion

This case demonstrates the feasibility of FG calibration during robotic paraesophageal hernia repair. Continuous visualization of the calibration device provided an additional intraoperative reference during dissection in the setting of distorted anatomy. This approach may offer improved orientation compared with conventional calibration techniques, although its effect on clinical outcomes remains unknown.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hernia, HiatalRobotic Surgical ProceduresHerniorrhaphyHumansFemaleAgedFundoplicationFluorescenceCalibration

Stichwörter der Autor:innen

Calibration tubeFluorescence-guided calibrationFluorescence-guided surgeryForegut surgeryParaesophageal hiatal hernia

Autor:innen und Institutionen

  • Department of Surgery, North Shore University Hospital, Zucker School of Medicine at Hofstra/Northwell, Manhasset, New York, USA. (Dr. Fontaine-Nicola).
  • Department of Surgery, West Virginia University, Morgantown, West Virginia, USA. (Drs. Harman, Hajjar, and Szoka).
  • Department of Surgery, University of California, San Diego, California, USA. (Dr. Reyes).

Zitieren

APA

Fontaine-Nicola, A., Harman, H., Reyes, E., Hajjar, M., & Szoka, N. (2026). Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair. CRSLS : MIS Case Reports from SLS. https://doi.org/10.4293/crsls.2026.00069

Vancouver

Fontaine-Nicola A, Harman H, Reyes E, Hajjar M, Szoka N. Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair. CRSLS : MIS Case Reports from SLS. 2026. doi:10.4293/crsls.2026.00069

BibTeX
@article{FontaineNicola2026,
  author = {Fontaine-Nicola, Andres and Harman, Hayley and Reyes, Edgardo and Hajjar, Mustafa and Szoka, Nova},
  title = {Novel Fluorescence-Guided Gastric Calibration Tube in Robotic Paraesophageal Hernia Repair},
  journal = {CRSLS : MIS Case Reports from SLS},
  year = {2026},
  doi = {10.4293/crsls.2026.00069}
}
Kostenlos starten →