Robotic Belsey Mark IV Repair of the Paraesophageal Hernia
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery · 2023
DOI: 10.1177/15569845221150014 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery, 2023. Verfasst von Joseph A Reza und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic Medicine and Surgery, Division of Thoracic Surgery, Temple University Hospital, Philadelphia, PA, USA. Hauptthemen laut MEDLINE: Hernia, Hiatal, Robotic Surgical Procedures, Laparoscopy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben.
Abstract (Originalsprache)
Objective
Surgical repair of paraesophageal hernias in patients with hostile abdomen is challenging. Despite its utility as an open procedure, the adoption of the minimally invasive Belsey Mark IV procedure has been limited because of the complexity of using traditional video-assisted thoracoscopic instrumentation. The robotic platform offers additional degrees of freedom, which enables minimally invasive transthoracic approach despite challenging anatomy. The purpose of this article is to describe a technique of robotic approach for the Belsey Mark IV operation.
Methods
We retrospectively reviewed 5 cases of the robotic Belsey Mark IV procedure completed at a single institution between June 2018 and November 2021. Data were collected from a review of the medical records, including operative reports, anesthesia records, imaging, and clinical notes. The operative technique is described in the present article. There were 4 men and 1 woman. The average age of the patients was 64.4 ± 13.6 years, with an average body mass index of 24.5 kg/m 2 . Three patients had undergone previous transabdominal hiatal hernia repair, and 2 of them had 2 prior repairs. One patient underwent simultaneous pulmonary left lower lobectomy for cancer with the Belsey Mark IV procedure.
Results
The average operative time was 209 ± 95 min (110 to 360 min). The average postoperative length of stay was 4.2 days, and 2 patients experienced complications including bleeding and persistent air leak (after lobectomy). The average blood loss was 67 ± 25 mL.
Conclusions
The robotic platform enables a transthoracic minimally invasive approach to the Belsey Mark IV operation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Thoracic Medicine and Surgery, Division of Thoracic Surgery, Temple University Hospital, Philadelphia, PA, USA.
- Department of Surgical Oncology, Division of Thoracic Surgery, Fox Chase Cancer Center, Philadelphia, PA, USA.
- Department of Surgery, Division of Thoracic Surgery, Brown University, Providence, RI, USA.
ORCID-Profile: Joseph A Reza, Charles Bakhos
Zitieren
APA
Reza, J. A., Bakhos, C., Su, S., Petrov, R., & Abbas, A. E. (2023). Robotic Belsey Mark IV Repair of the Paraesophageal Hernia. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. https://doi.org/10.1177/15569845221150014
Vancouver
Reza JA, Bakhos C, Su S, Petrov R, Abbas AE. Robotic Belsey Mark IV Repair of the Paraesophageal Hernia. Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 2023. doi:10.1177/15569845221150014
BibTeX
@article{Reza2023,
author = {Reza, Joseph A and Bakhos, Charles and Su, Stacey and Petrov, Roman and Abbas, Abbas E},
title = {Robotic Belsey Mark IV Repair of the Paraesophageal Hernia},
journal = {Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery},
year = {2023},
doi = {10.1177/15569845221150014}
}
EUVIMED