Development and Evaluation of a Real-Time Multi-Point Temperature and Humidity Monitoring System in Mechanical Ventilator Circuits

Takaaki Kato, Yusuke Fujii, Kazuki Aiki, Hiroshi Ichiyanagi

Iryou kikigaku (The Japanese journal of medical instrumentation) · 2026 · 96 (1) · 13-20

DOI: 10.4286/jjmi.96.13 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Iryou kikigaku (The Japanese journal of medical instrumentation), 2026. Verfasst von Takaaki Kato und 3 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Adequate humidification during mechanical ventilation is essential to protect airway mucosa, maintain mucociliary clearance, and prevent complications such as secretion retention and tube occlusion. Although heated humidifiers and heat and moisture exchangers (HME) are commonly used, only heated humidifiers can reliably deliver gas at physiological humidity levels (37°C, 100% RH, 44 mg/L AH). However, no commercially available system enables real-time, multi-point measurement of temperature and humidity within ventilator circuits. In this study, we developed a novel monitoring system comprising one Breathing Environment Monitoring and Analysis System (BEMAS) and four TH sensors to evaluate temperature and humidity at key points in the ventilator circuit. Four different ventilator models were tested using standardized settings in a controlled environment. Results revealed inter-device variation in delivered temperature and humidity, with absolute humidity levels in the test lung consistently below the physiological target. The system also captured cyclical fluctuations in temperature and humidity corresponding to inspiratory and expiratory phases. These findings highlight the need for better device-specific humidification strategies and suggest the clinical utility of real-time monitoring. Further refinements to sensor size and circuit integration are underway to improve accuracy and applicability in pediatric and adult patients.

Zitieren

APA

Kato, T., Fujii, Y., Aiki, K., & Ichiyanagi, H. (2026). Development and Evaluation of a Real-Time Multi-Point Temperature and Humidity Monitoring System in Mechanical Ventilator Circuits. Iryou kikigaku (The Japanese journal of medical instrumentation), 96(1), 13-20. https://doi.org/10.4286/jjmi.96.13

Vancouver

Kato T, Fujii Y, Aiki K, Ichiyanagi H. Development and Evaluation of a Real-Time Multi-Point Temperature and Humidity Monitoring System in Mechanical Ventilator Circuits. Iryou kikigaku (The Japanese journal of medical instrumentation). 2026;96(1):13-20. doi:10.4286/jjmi.96.13

BibTeX
@article{Kato2026,
  author = {Kato, Takaaki and Fujii, Yusuke and Aiki, Kazuki and Ichiyanagi, Hiroshi},
  title = {Development and Evaluation of a Real-Time Multi-Point Temperature and Humidity Monitoring System in Mechanical Ventilator Circuits},
  journal = {Iryou kikigaku (The Japanese journal of medical instrumentation)},
  year = {2026},
  volume = {96},
  number = {1},
  pages = {13--20},
  doi = {10.4286/jjmi.96.13}
}
Kostenlos starten →