Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study
Clinical Transplantation and Research · 2024
DOI: 10.4285/ctr.24.0007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Transplantation and Research, 2024. Verfasst von Nisha Rajmohan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Critical Care, Aster Medcity, Kochi, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Patients with chronic kidney disease (CKD) who undergo hemodialysis are predisposed to interstitial cerebral edema. Robotic-assisted laparoscopic surgery can increase optic nerve sheath diameter (ONSD) and intracranial pressure. The impact of robotic-assisted kidney transplant (RAKT) on ONSD is complicated by the presence of CKD, the administration of furosemide and mannitol, and the manipulation of hemodynamics. We examined ONSD variations in patients undergoing RAKT over a 1-year period at our institution. Furthermore, we attempted to identify any perioperative hemodynamic factors influencing these changes.
Methods
This prospective study included 20 patients undergoing RAKT. ONSD, heart rate, central venous pressure, systolic blood pressure, diastolic blood pressure (DBP), and mean arterial pressure (MAP) were measured following intubation (T1), after assuming the steep Trendelenburg position (T2), 1 hour after docking (T3), upon reperfusion (T4), after transition to the supine position (T5), and 3 hours postextubation (T6). Repeated measures analysis of variance with post hoc Bonferroni correction was employed to compare variables at each time point. Pearson correlation analysis was utilized to assess relationships between variables. P-values ≤0.05 were considered to indicate statistical significance.
Results
ONSD (in mm) increased from T1 (3.60±0.44) to T3 (4.06±0.45, P=0.002) and T4 (3.99±0.62, P=0.046), before falling to its lowest value at T6 (3.42±0.64, P=0.002). Pearson correlation analysis revealed significant correlations (P
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesia and Critical Care, Aster Medcity, Kochi, India.
ORCID-Profile: Nisha Rajmohan, Jithendra Thiruvathtra, Shilpa Omkarappa, Sangeeth Perath Srinivasan, Nidhin Eldo, Rajesh Rajgopal
Zitieren
APA
Rajmohan, N., Thiruvathtra, J., Omkarappa, S., Srinivasan, S. P., Eldo, N., & Rajgopal, R. (2024). Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study. Clinical Transplantation and Research. https://doi.org/10.4285/ctr.24.0007
Vancouver
Rajmohan N, Thiruvathtra J, Omkarappa S, Srinivasan SP, Eldo N, Rajgopal R. Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study. Clinical Transplantation and Research. 2024. doi:10.4285/ctr.24.0007
BibTeX
@article{Rajmohan2024,
author = {Rajmohan, Nisha and Thiruvathtra, Jithendra and Omkarappa, Shilpa and Srinivasan, Sangeeth Perath and Eldo, Nidhin and Rajgopal, Rajesh},
title = {Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study},
journal = {Clinical Transplantation and Research},
year = {2024},
doi = {10.4285/ctr.24.0007}
}
EUVIMED