EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study

Nisha Rajmohan iD, Jithendra Thiruvathtra iD, Shilpa Omkarappa iD, Sangeeth Perath Srinivasan iD, Nidhin Eldo iD, Rajesh Rajgopal iD

Clinical Transplantation and Research · 2024

DOI: 10.4285/ctr.24.0007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Clinical Transplantation and Research, 2024. Verfasst von Nisha Rajmohan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesia and Critical Care, Aster Medcity, Kochi, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Patients with chronic kidney disease (CKD) who undergo hemodialysis are predisposed to interstitial cerebral edema. Robotic-assisted laparoscopic surgery can increase optic nerve sheath diameter (ONSD) and intracranial pressure. The impact of robotic-assisted kidney transplant (RAKT) on ONSD is complicated by the presence of CKD, the administration of furosemide and mannitol, and the manipulation of hemodynamics. We examined ONSD variations in patients undergoing RAKT over a 1-year period at our institution. Furthermore, we attempted to identify any perioperative hemodynamic factors influencing these changes.

Methods

This prospective study included 20 patients undergoing RAKT. ONSD, heart rate, central venous pressure, systolic blood pressure, diastolic blood pressure (DBP), and mean arterial pressure (MAP) were measured following intubation (T1), after assuming the steep Trendelenburg position (T2), 1 hour after docking (T3), upon reperfusion (T4), after transition to the supine position (T5), and 3 hours postextubation (T6). Repeated measures analysis of variance with post hoc Bonferroni correction was employed to compare variables at each time point. Pearson correlation analysis was utilized to assess relationships between variables. P-values ≤0.05 were considered to indicate statistical significance.

Results

ONSD (in mm) increased from T1 (3.60±0.44) to T3 (4.06±0.45, P=0.002) and T4 (3.99±0.62, P=0.046), before falling to its lowest value at T6 (3.42±0.64, P=0.002). Pearson correlation analysis revealed significant correlations (P

Schlagwörter

Stichwörter der Autor:innen

Elevated intracranial pressureKidney transplantationsPneumoperitoneumRobotic-assisted surgeryTrendelenburg position

Autor:innen und Institutionen

  • Department of Anesthesia and Critical Care, Aster Medcity, Kochi, India.

ORCID-Profile: Nisha Rajmohan, Jithendra Thiruvathtra, Shilpa Omkarappa, Sangeeth Perath Srinivasan, Nidhin Eldo, Rajesh Rajgopal

Zitieren

APA

Rajmohan, N., Thiruvathtra, J., Omkarappa, S., Srinivasan, S. P., Eldo, N., & Rajgopal, R. (2024). Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study. Clinical Transplantation and Research. https://doi.org/10.4285/ctr.24.0007

Vancouver

Rajmohan N, Thiruvathtra J, Omkarappa S, Srinivasan SP, Eldo N, Rajgopal R. Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study. Clinical Transplantation and Research. 2024. doi:10.4285/ctr.24.0007

BibTeX
@article{Rajmohan2024,
  author = {Rajmohan, Nisha and Thiruvathtra, Jithendra and Omkarappa, Shilpa and Srinivasan, Sangeeth Perath and Eldo, Nidhin and Rajgopal, Rajesh},
  title = {Perioperative optic nerve sheath diameter variations in patients with end-stage renal failure undergoing robotic-assisted kidney transplant: a prospective observational study},
  journal = {Clinical Transplantation and Research},
  year = {2024},
  doi = {10.4285/ctr.24.0007}
}
Kostenlos starten →