EUVIMEDEUVIMED entdecken
Open Access

Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation

Emanuele Gallinoro, Pasquale Paolisso, Dario Tino Bertolone, Giuseppe Esposito, Marta Belmonte, Attilio Leone, Michele Mattia Viscusi, Monika Shumkova, Cristina De Colle, Ivan Degrieck, Filip Casselman, Martin Penicka und 7 weitere

EuroIntervention · 2024

DOI: 10.4244/eij-d-24-00075 ↗

Kurz gefasst

Fachartikel in der Zeitschrift EuroIntervention, 2024. Verfasst von Emanuele Gallinoro und 18 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Coronary Circulation, Vascular Resistance. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Severe aortic stenosis (AS) is associated with left ventricular (LV) remodelling, likely causing alterations in coronary blood flow and microvascular resistance. AIMS: We aimed to evaluate changes in absolute coronary flow and microvascular resistance in patients with AS undergoing transcatheter aortic valve implantation (TAVI). METHODS: Consecutive patients with AS undergoing TAVI with non-obstructive coronary artery disease in the left anterior descending artery (LAD) were included. Absolute coronary flow (Q) and microvascular resistance (Rμ) were measured in the LAD using continuous intracoronary thermodilution at rest and during hyperaemia before and after TAVI, and at 6-month follow-up. Total myocardial mass and LAD-specific mass were quantified by echocardiography and cardiac computed tomography. Regional myocardial perfusion (QN) was calculated by dividing absolute flow by the subtended myocardial mass. RESULTS: In 51 patients, Q and R were measured at rest and during hyperaemia before and after TAVI; in 20 (39%) patients, measurements were also obtained 6 months after TAVI. No changes occurred in resting and hyperaemic flow and resistance before and after TAVI nor after 6 months. However, at 6-month follow-up, a notable reverse LV remodelling resulted in a significant increase in hyperaemic perfusion (QN,hyper: 0.86 [interquartile range {IQR} 0.691.06] vs 1.20 [IQR 0.99-1.32] mL/min/g; p=0.008; pre-TAVI and follow-up, respectively) but not in resting perfusion (QN,rest: 0.34 [IQR 0.30-0.48] vs 0.47 [IQR 0.36-0.67] mL/min/g; p=0.06). CONCLUSIONS: Immediately after TAVI, no changes occurred in absolute coronary flow or coronary flow reserve. Over time, the remodelling of the left ventricle is associated with increased hyperaemic perfusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisCoronary CirculationVascular ResistanceHumansFemaleMaleAgedAged, 80 and overCoronary Artery DiseaseVentricular RemodelingTreatment OutcomeEchocardiographyAortic ValveCoronary Vessels

Autor:innen und Institutionen

  • Cardiovascular Center Aalst, OLV Clinic, Aalst, Belgium.
  • Division of University Cardiology, IRCCS Galeazzi - Sant'Ambrogio Hospital, Milan, Italy.
  • Department of Advanced Biomedical Sciences, University of Naples Federico II, Naples, Italy.
  • Department of Cardiology, Lausanne University Hospital, Lausanne, Switzerland.
  • Department of Clinical and Molecular Medicine, Sapienza University of Rome, Rome, Italy.

Zitieren

APA

Gallinoro, E., Paolisso, P., Bertolone, D. T., Esposito, G., Belmonte, M., Leone, A., Viscusi, M. M., Shumkova, M., De Colle, C., Degrieck, I., Casselman, F., Penicka, M., Collet, C., Sonck, J., Wyffels, E., Bartunek, J., De Bruyne, B., Vanderheyden, M., & Barbato, E. (2024). Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation. EuroIntervention. https://doi.org/10.4244/eij-d-24-00075

Vancouver

Gallinoro E, Paolisso P, Bertolone DT, Esposito G, Belmonte M, Leone A, et al. Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation. EuroIntervention. 2024. doi:10.4244/eij-d-24-00075

BibTeX
@article{Gallinoro2024,
  author = {Gallinoro, Emanuele and Paolisso, Pasquale and Bertolone, Dario Tino and Esposito, Giuseppe and Belmonte, Marta and Leone, Attilio and Viscusi, Michele Mattia and Shumkova, Monika and De Colle, Cristina and Degrieck, Ivan and Casselman, Filip and Penicka, Martin and Collet, Carlos and Sonck, Jeroen and Wyffels, Eric and Bartunek, Jozef and De Bruyne, Bernard and Vanderheyden, Marc and Barbato, Emanuele},
  title = {Absolute coronary flow and microvascular resistance before and after transcatheter aortic valve implantation},
  journal = {EuroIntervention},
  year = {2024},
  doi = {10.4244/eij-d-24-00075}
}
Kostenlos starten →