EUVIMEDOpdag EUVIMED
Open access · CC BY 4.0

Training benefits of virtual bronchoscopy prior to Endobronchial Ultrasound Guide sheath

D. Fielding, F. Bashirzadeh, P. Nguyen

Open Journal of Clinical Diagnostics · 2011

DOI: 10.4236/ojcd.2011.13003 ↗

At a glance

Journal article in Open Journal of Clinical Diagnostics, 2011. Written by D. Fielding and 2 co-authors. 18 references. The full text is freely available (open access, CC BY 4.0).

AbstractBibliografiske oplysningerCiteRelated studies

Abstract (original language)

Research questions. How does a virtual bronchoscopy navigation system (VBNS) improve prediction of candidate bronchus across a range of doctors investigating a range of lesions with Endobronchial ultrasound (EBUS) guide sheath? To what extent do benefits of virtual bronchoscopic pre-procedure navigation apply to experienced versus inexperienced bron- choscopists?

Methods

Using archived EBUS Guide sheath cases, a comparison was made between identified candidate 4th order bronchus by Computerised tomography (CT) evaluation versus that identified after virtual path creation.

Results

From 7 archived cases, 14 doctors identified the correct bronchus in 94 of 98 assessments (95%). Percentage of cases where there was an improvement in localisation by 2 or more 4th order bronchi was 39.8% overall (28.6% – 51.0%), 26.6 for experienced and 53.1 for inexperienced bronchoscopists (p < 0.02). The absolute mean number of 4th order bronchi different between CT and VBNS was 2.0 ± 2.6 overall, 1.2 (range 0-6) for experienced, and 2.8 (range 0-11) for inexperienced bronchoscopists. Virtual Path software calculation time was 8.1 ± 2.7 minutes, compared to 3.6 ± 2.1 minutes by CT.

Conclusion

VBNS allowed rapid accurate assessment with minimal software training. Greatest benefits in reduction of procedure time were obtained in inexperienced bronchoscopists, and VBNS could allow more rapid skill development in EBUS GS in these doctors.

Cite

APA

Fielding, D., Bashirzadeh, F., & Nguyen, P. (2011). Training benefits of virtual bronchoscopy prior to Endobronchial Ultrasound Guide sheath. Open Journal of Clinical Diagnostics. https://doi.org/10.4236/ojcd.2011.13003

Vancouver

Fielding D, Bashirzadeh F, Nguyen P. Training benefits of virtual bronchoscopy prior to Endobronchial Ultrasound Guide sheath. Open Journal of Clinical Diagnostics. 2011. doi:10.4236/ojcd.2011.13003

BibTeX
@article{Fielding2011,
  author = {Fielding, D. and Bashirzadeh, F. and Nguyen, P.},
  title = {Training benefits of virtual bronchoscopy prior to Endobronchial Ultrasound Guide sheath},
  journal = {Open Journal of Clinical Diagnostics},
  year = {2011},
  doi = {10.4236/ojcd.2011.13003}
}
Start for free →