EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, Smartarc<sup>TM</sup>, and 3D Conventional Radiation Therapy

Pamela Myers, Sotirios Stathakis, Alonso N. Gutiérrez, Carlos Esquivel, Panayiotis Mavroidis, Niko Papanikolaou

International Journal of Medical Physics, Clinical Engineering and Radiation Oncology · 2013

DOI: 10.4236/ijmpcero.2013.21005 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Medical Physics, Clinical Engineering and Radiation Oncology, 2013. Verfasst von Pamela Myers und 5 weiteren Autor:innen. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison was performed between tomotherapy, volumetric modulated arc therapy (VMAT), and 3D conformal radiation therapy (3D-CRT) for CSI. Methods and Materials: Five (n = 5) CSI patients were planned using 3D-CRT, VMAT, and tomotherapy (normalized such that 95% of PTV received at least 23.4 Gy in 13 fractions). Plans were compared using PTV conformity number (CN) and homogeneity index (HI), normal tissue (NT) dose statistics, integral dose, and treatment time.

Results

On average, tomotherapy plans showed higher CN (0.932 vs. 0.860 and 0.672 for SmartArc and 3D-CRT). In terms of HI, VMAT plans consistently showed better dose homogeneity (1.07 vs. 1.15 and 1.13 for tomotherapy and 3D-CRT). SmartArc delivered lower maximum dose for majority of NT, but higher mean dose. 3D-CRT plans delivered higher maximum dose but lower mean dose to NT.

Conclusions

SmartArc treatments achieved better PTV homogeneity and reduced maximum dose to NT. Tomotherapy showed better target conformity, but 3D-CRT was shown to reduce mean dose to NT. Integral doses were similar between treatment modalities, but tomotherapy treatment times were much longer.

Zitieren

APA

Myers, P., Stathakis, S., Gutiérrez, A. N., Esquivel, C., Mavroidis, P., & Papanikolaou, N. (2013). Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, SmartarcTM, and 3D Conventional Radiation Therapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. https://doi.org/10.4236/ijmpcero.2013.21005

Vancouver

Myers P, Stathakis S, Gutiérrez AN, Esquivel C, Mavroidis P, Papanikolaou N. Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, SmartarcTM, and 3D Conventional Radiation Therapy. International Journal of Medical Physics, Clinical Engineering and Radiation Oncology. 2013. doi:10.4236/ijmpcero.2013.21005

BibTeX
@article{Myers2013,
  author = {Myers, Pamela and Stathakis, Sotirios and Gutiérrez, Alonso N. and Esquivel, Carlos and Mavroidis, Panayiotis and Papanikolaou, Niko},
  title = {Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, SmartarcTM, and 3D Conventional Radiation Therapy},
  journal = {International Journal of Medical Physics, Clinical Engineering and Radiation Oncology},
  year = {2013},
  doi = {10.4236/ijmpcero.2013.21005}
}
Kostenlos starten →