Automated contouring, treatment planning, and quality assurance for VMAT craniospinal irradiation (VMAT-CSI)
Frontiers in Oncology · 10.04.2024 · 14
DOI: 10.3389/fonc.2024.1378449 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Oncology, online erschienen am 10.04.2024. Verfasst von Eric Simiele und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Stanford University, Stanford, CA, United States. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Create a comprehensive automated solution for pediatric and adult VMAT-CSI including contouring, planning, and plan check to reduce planning time and improve plan quality.
Methods
Seventy-seven previously treated CSI patients (age, 2-67 years) were used for creation of an auto-contouring model to segment 25 organs at risk (OARs). The auto-contoured OARs were evaluated using the Dice Similarity Coefficient (DSC), 95% Hausdorff Distance (HD95), and a qualitative ranking by one physician and one physicist (scale: 1-acceptable, 2-minor edits, 3-major edits). The auto-planning script was developed using the Varian Eclipse Scripting API and tested with 20 patients previously treated with either low-dose VMAT-CSI (12 Gy) or high-dose VMAT-CSI (36 Gy + 18 Gy boost). Clinically relevant metrics, planning time, and blinded physician review were used to evaluate significance of differences between the auto and manual plans. Finally, the plan preparation for treatment and plan check processes were automated to improve efficiency and safety of VMAT-CSI.
Results
The auto-contours achieved an average DSC of 0.71 ± 0.15, HD95 of 4.81 ± 4.68, and reviewers’ ranking of 1.22 ± 0.39, indicating close to “acceptable-as-is” contours. Compared to the manual CSI plans, the auto-plans for both dose regimens achieved statistically significant reductions in body V50% and D mean for parotids, submandibular, and thyroid glands. The variance in the dosimetric parameters decreased for the auto-plans as compared to the manual plans indicating better plan consistency. From the blinded review, the auto-plans were marked as equivalent or superior to the manual-plans 88.3% of the time. The required time for the auto-contouring and planning was consistently between 1-2 hours compared to an estimated 5-6 hours for manual contouring and planning.
Conclusions
Reductions in contouring and planning time without sacrificing plan quality were obtained using the developed auto-planning process. The auto-planning scripts and documentation will be made freely available to other institutions and clinics.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Stanford University, Stanford, CA, United States.
Zitieren
APA
Simiele, E., Romero, I. O., Wang, J. Y., Chen, Y., Lozko, Y., Severyn, Y., Skinner, L., Yang, Y., Xing, L., Gibbs, I., Hiniker, S. M., & Kovalchuk, N. (2024). Automated contouring, treatment planning, and quality assurance for VMAT craniospinal irradiation (VMAT-CSI). Frontiers in Oncology, 14. https://doi.org/10.3389/fonc.2024.1378449
Vancouver
Simiele E, Romero IO, Wang JY, Chen Y, Lozko Y, Severyn Y, et al. Automated contouring, treatment planning, and quality assurance for VMAT craniospinal irradiation (VMAT-CSI). Frontiers in Oncology. 2024;14. doi:10.3389/fonc.2024.1378449
BibTeX
@article{Simiele2024,
author = {Simiele, Eric and Romero, Ignacio O and Wang, Jen-Yeu and Chen, Yizheng and Lozko, Yuliia and Severyn, Yuliia and Skinner, Lawrie and Yang, Yong and Xing, Lei and Gibbs, Iris and Hiniker, Susan M and Kovalchuk, Nataliya},
title = {Automated contouring, treatment planning, and quality assurance for VMAT craniospinal irradiation (VMAT-CSI)},
journal = {Frontiers in Oncology},
year = {2024},
volume = {14},
doi = {10.3389/fonc.2024.1378449}
}
EUVIMED