EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Integration of locking screw fixation into 3D-printed patient-specific porous titanium implants enhances osseointegration: an in vivo study in a rabbit bone defect model

Kyu-Won Kang iD, Sook Yang iD, Sun Young Kim iD, Jihye Choi iD, Byung-Jae Kang iD

Journal of Veterinary Science · 2025 · 26 (5)

DOI: 10.4142/jvs.25179 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Science, 2025. Verfasst von Kyu-Won Kang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Clinical Sciences and Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, …. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Osseointegration, Titanium, Bone Screws. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

IMPORTANCE: Three-dimensional (3D) printing enables fabrication of patient-specific implants (PSIs) tailored to complex bone defects. Although locking screw fixation offers mechanical advantages in conventional plating, its integration into 3D-PSIs is technically challenging and has not been evaluated for biological outcomes. OBJECTIVE: This study aimed to assess whether locking screw fixation enhances osseointegration compared to nonlocking fixation when directly integrated into 3D-printed porous titanium implants. METHODS: Segmental femoral defects (20 mm) were created in ten adult rabbits, and customized porous Ti6Al4V implants were designed based on preoperative computed tomography (CT) scans. The implants incorporated threaded holes replicating the ARIX locking system and were fabricated via selective laser melting. Animals were randomly assigned to locking (n = 5) or nonlocking (n = 5) screw fixation groups. After 12 weeks, implant osseointegration was evaluated using radiography, micro-CT, and histological analyses. RESULTS: All implants remained stable without failure. Micro-CT revealed significantly higher bone volume fraction in the locking group (27.8% ± 3.7%) than the nonlocking group (23.8% ± 1.7%; p < 0.05). Histology showed more extensive and homogeneous bone ingrowth in the locking group, whereas fibrous tissue formation was observed in some nonlocking cases. The bone area percentage was significantly greater in the locking group (24.4% ± 9.9%) than in the nonlocking group (12.2% ± 7.1%; p < 0.05). CONCLUSIONS AND RELEVANCE: This study demonstrates that integrating locking screw fixation into 3D-printed porous titanium PSIs enhances osseointegration by improving primary stability. These findings suggest that locking fixation in PSI designs may improve outcomes for load-bearing bone defect reconstructions in veterinary and potentially human applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Printing, Three-DimensionalOsseointegrationTitaniumBone ScrewsFracture Fixation, InternalAnimalsRabbitsX-Ray MicrotomographyPorosityFemurMaleAlloys

Stichwörter der Autor:innen

3D-printed implantOsseointegrationlocking plate systempatient-specific implant

Substanzen

Titaniumtitanium alloy (TiAl6V4)Alloys

Autor:innen und Institutionen

  • Department of Veterinary Clinical Sciences and Research Institute for Veterinary Science, College of Veterinary Medicine, Seoul National University, Seoul 08826, Korea.
  • CUSMEDI Co., Ltd., Suwon 16675, Korea.
  • Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Purdue University, West Lafayette, IN 47907, USA.
  • BK21 FOUR Future Veterinary Medicine Leading Education and Research Center, Seoul National University, Seoul 08826, Korea. bjkang81@snu.ac.kr.

ORCID-Profile: Kyu-Won Kang, Sook Yang, Sun Young Kim, Jihye Choi, Byung-Jae Kang

Förderung

  • National Research Foundation of Korea

Zitieren

APA

Kang, K. W., Yang, S., Kim, S. Y., Choi, J., & Kang, B. J. (2025). Integration of locking screw fixation into 3D-printed patient-specific porous titanium implants enhances osseointegration: an in vivo study in a rabbit bone defect model. Journal of Veterinary Science, 26(5). https://doi.org/10.4142/jvs.25179

Vancouver

Kang KW, Yang S, Kim SY, Choi J, Kang BJ. Integration of locking screw fixation into 3D-printed patient-specific porous titanium implants enhances osseointegration: an in vivo study in a rabbit bone defect model. Journal of Veterinary Science. 2025;26(5). doi:10.4142/jvs.25179

BibTeX
@article{Kang2025,
  author = {Kang, Kyu-Won and Yang, Sook and Kim, Sun Young and Choi, Jihye and Kang, Byung-Jae},
  title = {Integration of locking screw fixation into 3D-printed patient-specific porous titanium implants enhances osseointegration: an in vivo study in a rabbit bone defect model},
  journal = {Journal of Veterinary Science},
  year = {2025},
  volume = {26},
  number = {5},
  doi = {10.4142/jvs.25179}
}
Kostenlos starten →