EUVIMEDEUVIMED entdecken
Open Access

Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2 * Image

Zikuan Chen, Vince Calhoun

Magnetic Resonance Insights · 2013

DOI: 10.4137/mri.s11920 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Insights, 2013. Verfasst von Zikuan Chen und 1 weiteren Autor:innen. Beteiligte Einrichtung: The Mind Research Network and LBERI, Albuquerque, NM. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and Purpose Recent research has shown that a T2 * image (either magnitude or phase) is not identical to the internal spatial distribution of a magnetic susceptibility (χ) source. In this paper, we examine the reasons behind these differences by looking into the insights of T2 * -weighted magnetic resonance imaging (T2 * MRI) and provide numerical characterizations of the source/image mismatches by numerical simulations.

Methods

For numerical simulations of T2 * MRI, we predefine a 3D χ source and calculate the complex-valued T2 * image by intravoxel dephasing in presence and absence of diffusion. We propose an empirical α-power model to describe the overall source/image transformation. For a Gaussian-shaped χ source, we numerically characterize the source/image morphological mismatch in terms of spatial correlation and FWHM (full width at half maximum).

Results

In theory, we show that the χ-induced fieldmap is morphologically different from the χ source due to dipole effect, and the T2 * magnitude image is related to the fieldmap by a quadratic transformation in the small phase angle regime, which imposes an additional morphological change. The numerical simulations with a Gaussian-shaped χ source show that a T2 * magnitude image may suffer an overall source/image morphological shrinkage of 20% to 25% and that the T2 * phase image is almost identical to the fieldmap thus maintaining a morphological mismatch from the χ source due to dipole effect.

Conclusion

The morphological mismatch between a bulk χ source and its T2 * image is caused by the 3D convolution during tissue magnetization (dipole effect), the nonlinearity of the T2 * magnitude and phase calculation, and the spin diffusion effect. In the small phase angle regime, the T2 * magnitude exhibits an overall morphological shrinkage, and the T2 * phase image suffers a dipole effect but maintains the χ-induced fieldmap morphology.

Schlagwörter

Stichwörter der Autor:innen

T2* magnitude imageT2* phase imageT2*-weighted magnetic resonance imaging (T2*MRI)T2*MRI nonlinearitydipole effectmagnetic susceptibility sourcemorphological shrinkagesign degeneracyspatial correlation

Autor:innen und Institutionen

  • The Mind Research Network and LBERI, Albuquerque, NM.
  • The Mind Research Network and LBERI, Albuquerque, NM. ; University of New Mexico, ECE Dept., Albuquerque, NM.

Förderung

  • NIBIB NIH HHS

Zitieren

APA

Chen, Z., & Calhoun, V. (2013). Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2 * Image. Magnetic Resonance Insights. https://doi.org/10.4137/mri.s11920

Vancouver

Chen Z, Calhoun V. Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2 * Image. Magnetic Resonance Insights. 2013. doi:10.4137/mri.s11920

BibTeX
@article{Chen2013,
  author = {Chen, Zikuan and Calhoun, Vince},
  title = {Understanding the Morphological Mismatch between Magnetic Susceptibility Source and T2 * Image},
  journal = {Magnetic Resonance Insights},
  year = {2013},
  doi = {10.4137/mri.s11920}
}
Kostenlos starten →