EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

Mechanical evaluation of EGUH burs in dentin during guided endodontics: Finite element analysis

Luis Geovanny Suárez Guerrero, Mauricio Aguirre Balseca, Karina Maria Salvatore Freitas, Maria Soledad Peñaherrera Manosalvas

Saudi Endodontic Journal · 2025

DOI: 10.4103/sej.sej_11_25 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Saudi Endodontic Journal, 2025. Verfasst von Luis Geovanny Suárez Guerrero und 3 weiteren Autor:innen. Die Arbeit nennt 15 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

This study investigated the mechanical and thermal behavior of EGUH burs used in guided endodontics through simulations performed using Finite Element Analysis. Materials and Methods: Geometric models of four EGUH burs (0.50 mm and 0.70 mm tips; 18 mm and 21 mm lengths) were developed using three-dimensional CAD software based on scans of a mandibular incisor. Finite Element Method simulations incorporated dentin and bur material properties from the literature, with boundary conditions replicating clinical parameters (loads of 0.49–1.47 N, 200,000–350,000 RPM, 37°C, 100% humidity). High-resolution tetrahedral meshing (up to 0.02 mm) and nonlinear contact modeling were applied to assess stress distribution, deformation, and thermal behavior. Mesh convergence and refinement ensured accuracy and stability in the simulations.

Results

Larger burs (0.70 mm) withstood 115 MPa and deformed only 0.01 mm, while smaller ones (0.50 mm) reached 80 MPa and deformed 0.03 mm. With guides, the stress in smaller burs dropped to 45 MPa. Thermal peaks were 45°C for small burs and 39.5°C for larger ones.

Conclusions

These results emphasize the relevance of selecting burs with geometries tailored to clinical demands. Larger diameter burs are recommended for extended or high-load procedures due to their mechanical and thermal advantages, whereas thinner burs require guiding systems to ensure safe and effective performance.

Zitieren

APA

Guerrero, L. G. S., Balseca, M. A., Freitas, K. M. S., & Manosalvas, M. S. P. (2025). Mechanical evaluation of EGUH burs in dentin during guided endodontics: Finite element analysis. Saudi Endodontic Journal. https://doi.org/10.4103/sej.sej_11_25

Vancouver

Guerrero LGS, Balseca MA, Freitas KMS, Manosalvas MSP. Mechanical evaluation of EGUH burs in dentin during guided endodontics: Finite element analysis. Saudi Endodontic Journal. 2025. doi:10.4103/sej.sej_11_25

BibTeX
@article{Guerrero2025,
  author = {Guerrero, Luis Geovanny Suárez and Balseca, Mauricio Aguirre and Freitas, Karina Maria Salvatore and Manosalvas, Maria Soledad Peñaherrera},
  title = {Mechanical evaluation of EGUH burs in dentin during guided endodontics: Finite element analysis},
  journal = {Saudi Endodontic Journal},
  year = {2025},
  doi = {10.4103/sej.sej_11_25}
}
Kostenlos starten →