Digital Evaluation of the Positional Accuracy of Implant Scan Bodies in All-On-Four Patients Using Digital Approach—A Controlled Clinical Trial
Journal of Pharmacy and Bioallied Sciences · 2026-07 · 18 (3) · 236-238
DOI: 10.4103/jpbs.jpbs_73_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Pharmacy and Bioallied Sciences, online erschienen am 10.07.2026. Verfasst von Y Vijaya Lakshmi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics Crown and Bridge, CKS Theja Institute of Dental Sciences & Research, Tirupathi, Andhra Pradesh, India. Die Arbeit nennt 9 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
A BSTRACT Aim: To compare the positional accuracy of the scan body obtained in indirect and direct–indirect digital approaches with that of the direct digital approach. Materials and Methods: Twenty implants were placed, each maxilla of four, using All-On-Four concept in five patients. Three impression techniques have been applied to each patient, namely 1) direct digital approach, 2) indirect digital approach, and 3) direct–indirect digital approach. With the use of specialized 3D inspection and metrology software, the difference in scan body position between the groups was calculated.
Results
The average total deviation values for the two groups under examination were 343.15 ± 3.4 μm and 402.79 ± 2.6 μm, respectively. For each of the study groups, the deviation measurement between the superimposed scan bodies revealed statistically significant ( P = 0.006) differences. A statistically insignificant difference between the compared groups was found by the post hoc analysis ( P = 0.006 and 0.014).
Conclusion
The direct–indirect digital impression group displayed the least positional accuracy (402.79 ± 2.6 μm). The accuracy of all three digital impression-making approaches in implant dentistry appears to be clinically acceptable and adequate for all types of implant restorations, especially in All-on-Four treatment modality.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Prosthodontics Crown and Bridge, CKS Theja Institute of Dental Sciences & Research, Tirupathi, Andhra Pradesh, India.
- Department of Oral and Maxillofacial Surgery, PES institute of Medical Sciences, Kuppam, Andhra Pradesh, India.
- Department of Prosthodontics Crown and Bridge, KGF College of Dental Sciences and Hospital, BEML Nagar, KGF, Karnataka, India.
- Department of Orthodontics and Dentofacial Orthopedics, CKS Theja Institute of Dental Sciences and Research, Tirupati, Andhra Pradesh, India.
- Department of Conservative Dentistry and Endodontics, Vijaya Multispeciality Dental Clinic, Tiruchanoor, Andhra Pradesh, India.
Zitieren
APA
Lakshmi, Y. V., Saketh, D. S., Dedeepya, N. R., Ramesh, P., Deepak, M. C., & Ankanna, T. (2026). Digital Evaluation of the Positional Accuracy of Implant Scan Bodies in All-On-Four Patients Using Digital Approach—A Controlled Clinical Trial. Journal of Pharmacy and Bioallied Sciences, 18(3), 236-238. https://doi.org/10.4103/jpbs.jpbs_73_26
Vancouver
Lakshmi YV, Saketh DS, Dedeepya NR, Ramesh P, Deepak MC, Ankanna T. Digital Evaluation of the Positional Accuracy of Implant Scan Bodies in All-On-Four Patients Using Digital Approach—A Controlled Clinical Trial. Journal of Pharmacy and Bioallied Sciences. 2026;18(3):236-238. doi:10.4103/jpbs.jpbs_73_26
BibTeX
@article{Lakshmi2026,
author = {Lakshmi, Y Vijaya and Saketh, D Sumanth and Dedeepya, N R and Ramesh, P and Deepak, Moulinath Chikati and Ankanna, T},
title = {Digital Evaluation of the Positional Accuracy of Implant Scan Bodies in All-On-Four Patients Using Digital Approach—A Controlled Clinical Trial},
journal = {Journal of Pharmacy and Bioallied Sciences},
year = {2026},
volume = {18},
number = {3},
pages = {236--238},
doi = {10.4103/jpbs.jpbs_73_26}
}