Biomechanical performance of poly-ether-ether-ketone (PEEK) vs. titanium orthodontic mini-screws in artificial bone: An in vitro investigation
Journal of Orthodontic Science · 2026-02 · 15 (1)
DOI: 10.4103/jos.jos_131_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Orthodontic Science, 2026-02. Verfasst von Aymen Adil Al-Hamadani und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
AIM AND OBJECTIVES: This study aimed to evaluate and compare the biomechanical behavior of titanium and poly-ether-ether-ketone (PEEK) orthodontic mini-screws. The objectives were to assess their performance through four biomechanical tests: maximum insertion torque (MIT), fracture torque (FT), vertical pull-out strength (VPS), and horizontal resistance (HR). MATERIALS AND METHODS: A total of 156 mini-screws (78 titanium, 78 PEEK), equally divided into 1.4 mm and 1.6 mm diameter groups, were inserted into artificial bone blocks under standardized in vitro conditions. Mechanical testing was conducted to evaluate each performance parameter. Data were analyzed using IBM statistical package for the social sciences (SPSS) software via one-way analysis of variance (ANOVA) or the Kruskal–Wallis test, depending on distribution, with a significance level of P < 0.05. RESULTS: The 1.6 mm PEEK group exhibited insertion torque comparable to titanium ( P > 0.05), although overall PEEK screws showed lower MIT values. In FT, VPS, and HR tests, PEEK screws frequently deformed, or fractured under loading, whereas titanium screws demonstrated significantly higher mechanical performance ( P < 0.001). CONCLUSION: Titanium mini-screws outperformed unreinforced PEEK screws across all mechanical tests, demonstrating superior torsional, pull-out, and lateral resistance. Additionally, larger-diameter screws (1.6 mm) showed better mechanical performance than smaller ones (1.4 mm) in both materials.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
Zitieren
APA
Al-Hamadani, A. A., & Alrubayee, M. A. (2026). Biomechanical performance of poly-ether-ether-ketone (PEEK) vs. titanium orthodontic mini-screws in artificial bone: An in vitro investigation. Journal of Orthodontic Science, 15(1). https://doi.org/10.4103/jos.jos_131_25
Vancouver
Al-Hamadani AA, Alrubayee MA. Biomechanical performance of poly-ether-ether-ketone (PEEK) vs. titanium orthodontic mini-screws in artificial bone: An in vitro investigation. Journal of Orthodontic Science. 2026;15(1). doi:10.4103/jos.jos_131_25
BibTeX
@article{AlHamadani2026,
author = {Al-Hamadani, Aymen Adil and Alrubayee, Mehdi Abdul-Hadi},
title = {Biomechanical performance of poly-ether-ether-ketone (PEEK) vs. titanium orthodontic mini-screws in artificial bone: An in vitro investigation},
journal = {Journal of Orthodontic Science},
year = {2026},
volume = {15},
number = {1},
doi = {10.4103/jos.jos_131_25}
}
EUVIMED