Comparison of Choroidal Vascular Index Measurements in Pachychoroid Pigment Epitheliopathy using Manual ImageJ-Based Niblack and Protocol-Standardized Otsu Thresholding
Journal of Current Ophthalmology · 2026-01 · 38 (1) · 55-60
DOI: 10.4103/joco.joco_25_26 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Journal of Current Ophthalmology, online erschienen am 06.08.2026. Verfasst von Doğukan Cömerter. Beteiligte Einrichtung: Department of Ophthalmology, Sultan Abdülhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
To compare choroidal vascular index (CVI) measurements obtained using manual ImageJ-based Niblack thresholding and protocol-standardized Otsu thresholding in patients with pachychoroid pigment epitheliopathy (PPE), employing a full-length choroidal region of interest (ROI) approach.
Methods
This retrospective observational study included 30 eyes of 30 patients diagnosed with PPE. Enhanced depth imaging–optical coherence tomography (EDI-OCT) scans were acquired using Heidelberg Spectralis. Both horizontal and vertical fovea-centered B-scans were analyzed. The ROI was manually delineated on the OCT device using the polygon selection tool to include the entire visible choroid from the retinal pigment epithelium/Bruch’s membrane complex to the choroidoscleral junction across the full scan width. CVI was calculated as the ratio of luminal area-to-total choroidal area. Manual ImageJ-based Niblack local thresholding was compared with protocol-standardized Otsu global thresholding using identical manually defined ROIs. Agreement was evaluated using paired t -tests, Pearson correlation, intraclass correlation coefficient (ICC), and Bland–Altman analysis.
Results
A total of 60 OCT B-scans were analyzed. Mean CVI values were 0.615 ± 0.030 for ImageJ-Niblack and 0.626 ± 0.052 for Otsu thresholding. The mean intermethod difference was +0.011 ± 0.028, with no statistically significant difference between methods ( P = 0.085). A strong linear association was observed ( r = 0.90, P < 0.001), and ICC (2,1) demonstrated good agreement (0.76). Bland–Altman analysis showed a small mean bias (+0.012) with 95% limits of agreement from −0.049 to +0.073. Because no external reference standard or prespecified clinical equivalence margin was available, the findings support methodological consistency rather than interchangeability or accuracy equivalence.
Conclusions
Protocol-standardized Otsu thresholding yielded CVI measurements that were directionally consistent with manual ImageJ-based Niblack analysis in PPE when a full-length choroidal ROI strategy was applied. This approach may support standardized group-level research analyses, but it should not be interpreted as establishing accuracy equivalence or full clinical interchangeability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Sultan Abdülhamid Han Training and Research Hospital, University of Health Sciences, Istanbul, Turkey.
Zitieren
APA
Cömerter, D. (2026). Comparison of Choroidal Vascular Index Measurements in Pachychoroid Pigment Epitheliopathy using Manual ImageJ-Based Niblack and Protocol-Standardized Otsu Thresholding. Journal of Current Ophthalmology, 38(1), 55-60. https://doi.org/10.4103/joco.joco_25_26
Vancouver
Cömerter D. Comparison of Choroidal Vascular Index Measurements in Pachychoroid Pigment Epitheliopathy using Manual ImageJ-Based Niblack and Protocol-Standardized Otsu Thresholding. Journal of Current Ophthalmology. 2026;38(1):55-60. doi:10.4103/joco.joco_25_26
BibTeX
@article{Cmerter2026,
author = {Cömerter, Doğukan},
title = {Comparison of Choroidal Vascular Index Measurements in Pachychoroid Pigment Epitheliopathy using Manual ImageJ-Based Niblack and Protocol-Standardized Otsu Thresholding},
journal = {Journal of Current Ophthalmology},
year = {2026},
volume = {38},
number = {1},
pages = {55--60},
doi = {10.4103/joco.joco_25_26}
}
EUVIMED