Commissioning and Quality Assurance of Catalyst+ HD Surface-guided Radiotherapy on TrueBeam HyperArc Linear Accelerator: An Indian Experience in Precision Radiotherapy
Journal of Medical Physics · 2025-04 · 50 (2) · 288-296
DOI: 10.4103/jmp.jmp_36_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 03.07.2025. Verfasst von Adhimoolam Saravana Kumar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Objective: In this study, we describe and critically review our experience in the commissioning of the surface-guided radiation therapy (SGRT) system from C-RAD (Uppsala, Sweden), integrated with a Varian TrueBeam HyperArc linear accelerator (LINAC). Materials and Methods: The C-RAD SGRT system was commissioned according to the guidelines of the American Association of Physicists in Medicine Task Group 147 and the European Society for Radiotherapy and Oncology–Advisory Committee for Radiation Oncology Practice report. The commissioning tests included the isocenter, camera thermal drift, reproducibility, static localization accuracy with a 6-degree-of-freedom (DOF) couch, dynamic gating delivery, and an end-to-end test. The tools and phantoms employed for this verification included: (a) Sentinel 4DCT daily check device, (b) Catalyst⁺ HD daily check device, (c) Penta-guide, (d) gating phantom, (e) calibration board, (f) Winston-Lutz phantom, and (g) the Little John anthropomorphic phantom. Results/Discussion: The reproducibility of both the Sentinel 4DCT and Catalyst⁺ HD cameras demonstrated accuracy within ± 1 mm. The radiation isocenter measurements for both the Sentinel 4DCT and Catalyst⁺ HD cameras were found to be
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Physics, PSG Hospitals, Coimbatore, Tamil Nadu, India.
- Fred Hutchinson Cancer Center, University of Washington, Seattle, WA, USA.
- International Center for Theoretical Physics, Trieste, Italy.
Zitieren
APA
Kumar, A. S., Meyer, J., Babu, A. D., Sankar, S., & Marco, E. (2025). Commissioning and Quality Assurance of Catalyst+ HD Surface-guided Radiotherapy on TrueBeam HyperArc Linear Accelerator: An Indian Experience in Precision Radiotherapy. Journal of Medical Physics, 50(2), 288-296. https://doi.org/10.4103/jmp.jmp_36_25
Vancouver
Kumar AS, Meyer J, Babu AD, Sankar S, Marco E. Commissioning and Quality Assurance of Catalyst+ HD Surface-guided Radiotherapy on TrueBeam HyperArc Linear Accelerator: An Indian Experience in Precision Radiotherapy. Journal of Medical Physics. 2025;50(2):288-296. doi:10.4103/jmp.jmp_36_25
BibTeX
@article{Kumar2025,
author = {Kumar, Adhimoolam Saravana and Meyer, Juergen and Babu, A Dinesh and Sankar, Sekar and Marco, Esposito},
title = {Commissioning and Quality Assurance of Catalyst+ HD Surface-guided Radiotherapy on TrueBeam HyperArc Linear Accelerator: An Indian Experience in Precision Radiotherapy},
journal = {Journal of Medical Physics},
year = {2025},
volume = {50},
number = {2},
pages = {288--296},
doi = {10.4103/jmp.jmp_36_25}
}
EUVIMED