A Combined Loss-driven Framework for Automated Parotid Segmentation in Head-and-Neck Computed Tomography
Journal of Medical Physics · 2025-07 · 50 (3) · 525-532
DOI: 10.4103/jmp.jmp_169_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Physics, online erschienen am 29.09.2025. Verfasst von Aryan Tyagi und 4 weiteren Autor:innen. Beteiligte Einrichtung: University School of Automation and Robotics, Guru Gobind Singh Indraprastha University, New Delhi, India. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Purpose
This study presents a deep learning framework for automatic parotid segmentation using three-dimensional (3D) U-Net and attention-augmented 3D U-Net architectures trained with a novel combined loss function tailored for anatomical accuracy and class imbalance. Materials and Methods: A curated dataset of 379 noncontrast head-and-neck computed tomography scans with expert-verified contours was used. Two architectures a residual 3D U-Net and its attention-enhanced variant were implemented using TensorFlow. The networks were trained with both categorical cross-entropy and a proposed combined loss integrating modified Dice Score Coefficient (mDSC) and focal loss (FL) with weights 0.7 and 0.3. The models were evaluated using dice similarity coefficient (DSC), Intersection over Union (IoU), and categorical accuracy. A custom checkpointing strategy was designed to preserve model weights corresponding to both peak DSC and minimum validation loss. The code and pretrained models are hosted on a publicly available GitHub repository at: https://github.com/1aryantyagi/Segmentation-Paper.
Results
The 3D U-Net trained with the combined loss achieved a median Dice score of 0.8835 (left parotid) and 0.8709 (right), with mean IoU values of 0.7672 and 0.7358, indicating strong segmentation accuracy. The U-Net produced comparable results, supporting the combined loss’s consistency. Bland–Altman analysis confirmed reduced variability and improved agreement.
Conclusion
The integration of mDSC and FL within a 3D U-Net architecture significantly improves segmentation performance, robustness, and spatial precision. These findings support the clinical feasibility of the proposed framework for automated, reproducible parotid delineation in radiotherapy planning.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University School of Automation and Robotics, Guru Gobind Singh Indraprastha University, New Delhi, India.
- Department of Radiotherapy, LLRM Medical College, Meerut, Uttar Pradesh, India.
- Division of Medical Physics, Rajiv Gandhi Cancer Hospital and Research Centre, Rohini, New Delhi, India.
- Department of Radiation Oncology, Andromeda Cancer Hospital, Kundli, Sonipat, Haryana, India.
- Department of Radiation Oncology, Max Super Speciality Hospital, Shalimar Bagh, New Delhi, India.
Zitieren
APA
Tyagi, A., Kumar, A., Singh, S., Manav, M., & Pal, S. (2025). A Combined Loss-driven Framework for Automated Parotid Segmentation in Head-and-Neck Computed Tomography. Journal of Medical Physics, 50(3), 525-532. https://doi.org/10.4103/jmp.jmp_169_25
Vancouver
Tyagi A, Kumar A, Singh S, Manav M, Pal S. A Combined Loss-driven Framework for Automated Parotid Segmentation in Head-and-Neck Computed Tomography. Journal of Medical Physics. 2025;50(3):525-532. doi:10.4103/jmp.jmp_169_25
BibTeX
@article{Tyagi2025,
author = {Tyagi, Aryan and Kumar, Anuj and Singh, Sandeep and Manav, Mohini and Pal, Soniya},
title = {A Combined Loss-driven Framework for Automated Parotid Segmentation in Head-and-Neck Computed Tomography},
journal = {Journal of Medical Physics},
year = {2025},
volume = {50},
number = {3},
pages = {525--532},
doi = {10.4103/jmp.jmp_169_25}
}
EUVIMED