EUVIMEDEUVIMED entdecken
Open Access

Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations

Rui Zhang, Yibo Xie, Chloe DiTusa, Raymond Ohler, David Heins, Daniel Bourgeois, Beibei Guo

Journal of Medical Physics · 2022-04 · 47 (2) · 166-172

DOI: 10.4103/jmp.jmp_146_21 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Medical Physics, 2022-04. Verfasst von Rui Zhang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Unflattened photon beams exhibit many benefits over traditional flattened beams for radiotherapy (RT), but comprehensive evaluations of dosimetric results and beam-on time using flattening filter-free (FFF) beams for all types of breast irradiations are still lacking. The purpose of this study was to investigate if FFF RT can maintain equal or better dose coverage than standard flattened-beam RT while reducing doses to organs at risk (OARs) and beam-on time for various types of breast cancer irradiations. Methods and Materials: FFF volumetric-modulated arc therapy (FFF-VMAT) and standard VMAT (STD-VMAT) treatment plans were created for 15 whole-breast irradiation (WBI) patients with 50 Gy/25 fractions, 13 partial-breast irradiation (PBI) patients with 38.5 Gy/10 fractions, and 9 postmastectomy irradiation (PMI) patients with 50 Gy/25 fractions. Planning target volume (PTV) coverage and dose to OARs were evaluated.

Results

Both techniques produced clinically acceptable plans for all three types of irradiations. For WBI, FFF-VMAT plans exhibited similar PTV and OARs evaluation metrics as STD-VMAT. For PBI, FFF-VMAT plans showed significantly lower mean and maximum doses for ipsilateral and contralateral lungs, contralateral breast, and heart. For PMI, FFF-VMAT plans showed significantly lower mean dose and V 5 for contralateral breast but significantly higher D mean , D max , and V 20 for ipsilateral lung and significantly higher D mean , V 22.5, and V 30 for heart. FFF-VMAT techniques significantly reduced beam-on time than STD-VMAT for all cases.

Conclusion

This work has shown that FFF beams are most beneficial for small-field irradiation such as PBI, and breast cancer patients could potentially benefit from the shortened beam-on time.

Schlagwörter

Stichwörter der Autor:innen

Breast cancerflattening filter-freepartial-breast irradiationpostmastectomy irradiationvolumetric-modulated arc therapywhole-breast irradiation

Autor:innen und Institutionen

  • Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA, USA.
  • Department of Radiation Oncology, Mary Bird Perkins Cancer Center, Baton Rouge, LA, USA.
  • Department of Biological Sciences, Louisiana State University, Baton Rouge, LA, USA.
  • Department of Radiation Oncology, CTSI Physics Services, Springfield, MO, USA.
  • Department of Radiation Oncology, Slidell Memorial Regional Cancer Center, Slidell, LA, USA.
  • Department of Experimental Statistics, Louisiana State University, Baton Rouge, LA, USA.

Förderung

  • NCI NIH HHS

Zitieren

APA

Zhang, R., Xie, Y., DiTusa, C., Ohler, R., Heins, D., Bourgeois, D., & Guo, B. (2022). Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations. Journal of Medical Physics, 47(2), 166-172. https://doi.org/10.4103/jmp.jmp_146_21

Vancouver

Zhang R, Xie Y, DiTusa C, Ohler R, Heins D, Bourgeois D, et al. Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations. Journal of Medical Physics. 2022;47(2):166-172. doi:10.4103/jmp.jmp_146_21

BibTeX
@article{Zhang2022,
  author = {Zhang, Rui and Xie, Yibo and DiTusa, Chloe and Ohler, Raymond and Heins, David and Bourgeois, Daniel and Guo, Beibei},
  title = {Flattening Filter-Free Volumetric-Modulated Arc Radiotherapy for Left-Sided Whole-Breast, Partial-Breast, and Postmastectomy Irradiations},
  journal = {Journal of Medical Physics},
  year = {2022},
  volume = {47},
  number = {2},
  pages = {166--172},
  doi = {10.4103/jmp.jmp_146_21}
}
Kostenlos starten →