Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy
Physics and Imaging in Radiation Oncology · 2026-11 · 42 · 101115
DOI: 10.1016/j.phro.2026.101115 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physics and Imaging in Radiation Oncology, 2026-11. Verfasst von Anne Caroline Knöchelmann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiotherapy, Hannover Medical School, Carl-Neuberg-Strasse 1, Hannover, 30625, Germany. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and purpose: Tangential volumetric modulated arc therapy may combine rotational conformality with tangential beam geometry. We compared tangential with continuous-arc volumetric modulated arc therapy for postoperative breast radiotherapy with deliberately matched target coverage, focusing on cardiac and contralateral low-dose exposure. Material and methods: Fifty-four patients were included in this paired planning study. For each patient, the clinically delivered tangential plan and a matched continuous-arc plan were evaluated. Target coverage was matched by clinical-target-volume D95% and planning-target-volume D2%. Dose-volume endpoints, low-dose area-under-the-curve metrics, delta dose-volume histograms, subgroup interactions, and mechanistic organ-equivalent-dose surrogates were evaluated.
Results
Target coverage and homogeneity were comparable, while conformity was higher with tangential planning (p = 0.006). Tangential planning reduced mean heart dose from 1.34 to 1.17 Gy (p < 0.001), contralateral lung mean dose from 0.94 to 0.57 Gy, and contralateral breast mean dose from 1.16 to 0.76 Gy (both p < 0.001). Mechanistic organ-equivalent-dose surrogates were reduced by 37.0% for the contralateral lung and 32.7% for the contralateral breast. Exploratory interaction analyses did not identify statistically significant interactions by laterality, deep-inspiration breath hold, simultaneous integrated boost, or regional nodal irradiation.
Conclusions
In a clinically heterogeneous paired cohort that included boost irradiation, regional nodal irradiation, and deep-inspiration breath hold, tangential volumetric modulated arc therapy reduced cardiac and contralateral low-dose exposure while preserving target coverage.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiotherapy, Hannover Medical School, Carl-Neuberg-Strasse 1, Hannover, 30625, Germany.
Zitieren
APA
Knöchelmann, A. C., Fischer, M., Burchardt, K., Meinecke, D., & Becker, J. N. (2026). Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy. Physics and Imaging in Radiation Oncology, 42, 101115. https://doi.org/10.1016/j.phro.2026.101115
Vancouver
Knöchelmann AC, Fischer M, Burchardt K, Meinecke D, Becker JN. Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy. Physics and Imaging in Radiation Oncology. 2026;42:101115. doi:10.1016/j.phro.2026.101115
BibTeX
@article{Knchelmann2026,
author = {Knöchelmann, Anne Caroline and Fischer, Mirko and Burchardt, Kathrin and Meinecke, Daniela and Becker, Jan-Niklas},
title = {Tangential volumetric modulated arc therapy reduces cardiac and contralateral low-dose exposure compared with continuous volumetric modulated arc therapy in postoperative breast radiotherapy},
journal = {Physics and Imaging in Radiation Oncology},
year = {2026},
volume = {42},
pages = {101115},
doi = {10.1016/j.phro.2026.101115}
}
EUVIMED