Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study
Journal of Indian Society of Pedodontics and Preventive Dentistry · 2024-07 · 42 (3) · 195-202
DOI: 10.4103/jisppd.jisppd_233_24 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Journal of Indian Society of Pedodontics and Preventive Dentistry, online erschienen am 09.09.2024. Verfasst von Rishabh Patel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pedodontics and Preventive Dentistry, ACPM Dental College, Dhule, Maharashtra, India. Hauptthemen laut MEDLINE: Microscopy, Electron, Scanning, Root Canal Preparation, Smear Layer. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
Context
The smear layer may harbor many bacteria; hence, alternative methods are used to disrupt and remove biofilm.
Aim
The aim of the study was to compare the effectiveness of EndoActivator, PATS Vario System, and XP-endo Finisher files on smear layer removal using a scanning electron microscope. Subjects and Methods: Sixty single-rooted extracted premolars with Vertucci Type 1 configuration were decoronated and divided into four groups. The groups were instrumented with the rotary ProTaper file system. All specimens were flushed with 1 ml of 3% sodium hypochlorite. Group 1 was irrigated with a conventional needle and syringe. In Group 2, the irrigant was activated with an EndoActivator. In Group 3, the irrigant was activated with PATS Vario system, and in Group 4, XP-endo Finisher files were used after biomechanical preparation to remove debris and smear layer. All specimens were finally rinsed with 3 ml of 3% sodium hypochlorite. The teeth underwent longitudinal splitting and grooving in the coronal, middle, and apical thirds, and then, the samples were taken for scanning electron microscopy to evaluate the amount of smear layer removal in each third.
Results
The middle and coronal thirds Showed that almost similar efficacy to remove smear layer in both Group II and Group III. At the apical third, Group III showed comparatively better results than Group I, II, and IV, respectively.
Conclusion
Equal amount of smear layer was seen with EndoActivator and PATS Vario system when used as sonic irrigation devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Pedodontics and Preventive Dentistry, ACPM Dental College, Dhule, Maharashtra, India.
Zitieren
APA
Patel, R., Shinde, G., Bondarde, P., Vishwakarma, A., Bhandare, M., & Pharne, V. (2024). Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study. Journal of Indian Society of Pedodontics and Preventive Dentistry, 42(3), 195-202. https://doi.org/10.4103/jisppd.jisppd_233_24
Vancouver
Patel R, Shinde G, Bondarde P, Vishwakarma A, Bhandare M, Pharne V. Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study. Journal of Indian Society of Pedodontics and Preventive Dentistry. 2024;42(3):195-202. doi:10.4103/jisppd.jisppd_233_24
BibTeX
@article{Patel2024,
author = {Patel, Rishabh and Shinde, Gaurav and Bondarde, Prashant and Vishwakarma, Aruna and Bhandare, Madhuri and Pharne, Vaibhavi},
title = {Effectiveness of EndoActivator, PATS Vario system, and XP-endo Finisher files on smear layer removal under scanning electron microscope: A comparative study},
journal = {Journal of Indian Society of Pedodontics and Preventive Dentistry},
year = {2024},
volume = {42},
number = {3},
pages = {195--202},
doi = {10.4103/jisppd.jisppd_233_24}
}
EUVIMED