Smear layer removal comparing conventional irrigation, passive ultrasonic irrigation, EndoActivator System, and a new sonic device (Perfect Clean System) by scanning electron microscopy: An ex vivo study
PLOS ONE · 27.12.2024 · 19 (12) · e0314940
DOI: 10.1371/journal.pone.0314940 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift PLOS ONE, online erschienen am 27.12.2024. Verfasst von Bruna Fernanda Alionço Gonçalves und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Endodontics, School of Health and Biosciences, Pontifical Catholic University of Paraná -PUC/PR, Curitiba, Paraná, Brazil. Hauptthemen laut MEDLINE: Microscopy, Electron, Scanning, Therapeutic Irrigation, Smear Layer. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Aim
This study evaluated the smear layer removal provided by conventional, sonic, and ultrasonic irrigation techniques. Methodology Forty extracted human mandibular first premolars were selected and instrumented using the ProTaper Next System files and 2.5% sodium hypochlorite. Afterward, they were divided into 4 groups (n. 10) according to the irrigation technique used to perform the final irrigation with a chelating solution (17% EDTA): conventional irrigation (CI), passive ultrasonic irrigation (PUI), EndoActivator System (EAS), and Perfect Clean System (PCS). The smear layer removal was determined through a score after evaluating scanning electron microscope images (1.000x) obtained at 1, 5, 8, and 12mm from the working length (WL). Statistical analyses were carried out by the Kruskal-Wallis and Dunn’s tests with a significance level of 5% (P < 0.05).
Results
All irrigation techniques were unable to promote an effective smear layer removal at 1mm from the WL in comparison with the other locations (P < .05). At 5, 8, and 12mm from the WL, no statistically significant differences were observed among CI, PUI, EAS, and PCS (P > 0.05). At 12mm from the WL, statistically significant differences were only identified after comparing PCS and CI (P < .05).
Conclusion
The smear layer removal was only efficient at 5, 8, and 12 from the WL with no significant statistical differences among CI, PUI, EAS, and PCS (P > 0.05).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Endodontics, School of Health and Biosciences, Pontifical Catholic University of Paraná -PUC/PR, Curitiba, Paraná, Brazil.
- Advanced Standing for International Dentist Program-ASPID Program, Health Sciences Center, College of Dentistry, University of Oklahoma, Oklahoma City, Oklahoma, United States of America.
- Health Sciences Center, Division of Endodontics, Department of Restorative Sciences, College of Dentistry, University of Oklahoma, Oklahoma City, Oklahoma, United States of America.
- Department of Materials Science, Polytechnical School, Pontifical Catholic University of Paraná -PUC/PR, Curitiba, Paraná, Brazil.
- Department of Biostatistics, School of Health and Biosciences, Pontifical Catholic University of Paraná -PUC/PR, Curitiba, Paraná, Brazil.
ORCID-Profile: Ricardo Machado
Zitieren
APA
Gonçalves, B. F. A., Reddy, D., Machado, R., Soares Júunior, P. C., Ignácio, S. A., Fernandes Couto, D. A., Frasquetti, K. S., Ditzel Westphalen, V. P., Carneiro, E., & Silva Neto, U. X. D. (2024). Smear layer removal comparing conventional irrigation, passive ultrasonic irrigation, EndoActivator System, and a new sonic device (Perfect Clean System) by scanning electron microscopy: An ex vivo study. PLOS ONE, 19(12), e0314940. https://doi.org/10.1371/journal.pone.0314940
Vancouver
Gonçalves BFA, Reddy D, Machado R, Soares Júunior PC, Ignácio SA, Fernandes Couto DA, et al. Smear layer removal comparing conventional irrigation, passive ultrasonic irrigation, EndoActivator System, and a new sonic device (Perfect Clean System) by scanning electron microscopy: An ex vivo study. PLOS ONE. 2024;19(12):e0314940. doi:10.1371/journal.pone.0314940
BibTeX
@article{Gonalves2024,
author = {Gonçalves, Bruna Fernanda Alionço and Reddy, Divya and Machado, Ricardo and Soares Júunior, Paulo César and Ignácio, Sérgio Aparecido and Fernandes Couto, Douglas Augusto and Frasquetti, Karine Santos and Ditzel Westphalen, Vânia Portela and Carneiro, Everdan and Silva Neto, Ulisses Xavier da},
title = {Smear layer removal comparing conventional irrigation, passive ultrasonic irrigation, EndoActivator System, and a new sonic device (Perfect Clean System) by scanning electron microscopy: An ex vivo study},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {12},
pages = {e0314940},
doi = {10.1371/journal.pone.0314940}
}