Incidence of straight and angulated screw channel following immediate implant placement in esthetic zone: A simulated cone-beam computed tomography study
PLOS ONE · 05.09.2024 · 19 (9) · e0308158
DOI: 10.1371/journal.pone.0308158 ↗Kurz gefasst
Fachartikel in der Zeitschrift PLOS ONE, online erschienen am 05.09.2024. Verfasst von Watcharapon Radomsutthisarn und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Bone Screws, Immediate Dental Implant Loading. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Statement of problem The demand for immediate implant placement (IIP) in the esthetic zone is rapidly increasing. Despite the treatment’s benefits, the sagittal root position often dictates implant angulation, commonly necessitating the use of cement-retained restorations. This study investigates the impact of angulated screw channel on IIP in the esthetic zone.
Purpose
The purpose of this cone-beam computed tomography (CBCT) study was to determine the probability of IIP in the esthetic zone, using four different implant angulations. Materials and methods A retrospective review of CBCT images was conducted and accessed on 9 June 2021. The midsagittal images of maxillary anterior teeth were input into an implant planning software (Implant Studio®). Bone Level X Straumann® implant (BLX 3.5, 3.75, 4.0, 4.5, 5.0 mm) and Bone Level Tapered implant (BLT 2.9, 3.3 mm) were selected for 3D implant planning of IIP in the esthetic zone. The frequency distribution and probability of IIP were recorded and compared among all maxillary anterior teeth.
Results
CBCT images from 720 teeth (120 patient) were evaluated, revealing an overall probability of IIP in the esthetic zone is 76.11% (548/720). Different implant restoration type was evaluated in this study, with the following results; straight screw-retained prosthesis at 3.47% (19/548), cement-retained prosthesis at 14.59% (80/548) and angle screw-retained prosthesis at 85.40% (468/548).
Conclusion
IIP with traditional straight screw-retained prosthesis demonstrated the lowest probability. Nevertheless, the use of angulated screw channels enhances the probability of achieving straight screw-retained prostheses. Clinical implications The angulated screw channel is essential for increasing the probability of screw-retained prosthesis in IIP in the esthetic zone. However, limitation in screw angle correction still necessitate the use of cement-retained prostheses for numbers of patients undergoing IIP.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Advanced General Dentistry, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
- Department of Oral and Maxillofacial Radiology, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
ORCID-Profile: Watcharapon Radomsutthisarn, Pranai Nakaparksin
Zitieren
APA
Radomsutthisarn, W., Kretapirom, K., & Nakaparksin, P. (2024). Incidence of straight and angulated screw channel following immediate implant placement in esthetic zone: A simulated cone-beam computed tomography study. PLOS ONE, 19(9), e0308158. https://doi.org/10.1371/journal.pone.0308158
Vancouver
Radomsutthisarn W, Kretapirom K, Nakaparksin P. Incidence of straight and angulated screw channel following immediate implant placement in esthetic zone: A simulated cone-beam computed tomography study. PLOS ONE. 2024;19(9):e0308158. doi:10.1371/journal.pone.0308158
BibTeX
@article{Radomsutthisarn2024,
author = {Radomsutthisarn, Watcharapon and Kretapirom, Kornkamol and Nakaparksin, Pranai},
title = {Incidence of straight and angulated screw channel following immediate implant placement in esthetic zone: A simulated cone-beam computed tomography study},
journal = {PLOS ONE},
year = {2024},
volume = {19},
number = {9},
pages = {e0308158},
doi = {10.1371/journal.pone.0308158}
}
EUVIMED