Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study
The Journal of Indian Prosthodontic Society · 2025
DOI: 10.4103/jips.jips_8_24 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift The Journal of Indian Prosthodontic Society, 2025. Verfasst von Manish Jangade und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Prosthodontics (Unit of Dentistry), Smt. Indira Gandhi Memorial Government Medical College, Kanker, Chhattishgarh, India. Hauptthemen laut MEDLINE: Zirconium, Ketones, Benzophenones, Computer-Aided Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Aim
The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions. Settings and Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line. Materials and Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone. The dies were divided into two groups: Group-A (PEEK) copings and Group-B (zirconia) copings. All copings were fabricated using a CAD/CAM system. Vertical marginal accuracy was assessed with a stereomicroscope and image analysis software at ×20 magnification. The marginal ga P values were subjected to a student (independent) t -test for statistical analysis. Statistical Analysis Used: The statistical analysis involved a student (independent) t -test to compare the marginal ga P values between Group A (PEEK) and Group B (zirconia).
Results
The mean marginal discrepancy for Group A (PEEK) and Group B (zirconia) was 92.84 μm ± 3.48 μm and 63.12 μm ± 31.47 μm, respectively. A statistically significant variation ( t = 3.635, P = 0.001) between the groups was observed, indicating better marginal accuracy with zirconia copings compared to PEEK copings.
Conclusion
Both PEEK and zirconia copings demonstrated vertical marginal discrepancies within the clinically acceptable limit of
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Prosthodontics (Unit of Dentistry), Smt. Indira Gandhi Memorial Government Medical College, Kanker, Chhattishgarh, India.
- Department of Prosthodontics, Rungta College of Dental Sciences and Research, Bhilai, Chhattishgarh, India.
- Division of Prosthodontics, Christian Dental College, Ludhiana, Punjab, India.
- Department of Prosthodontics, Chhattisgarh Dental College and Hospital, Rajnandgaon, Chhattishgarh, India.
Zitieren
APA
Jangade, M., Sharma, R., Sudharson, N. A., Jain, R., Sahu, S. K., & Dani, A. (2025). Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_8_24
Vancouver
Jangade M, Sharma R, Sudharson NA, Jain R, Sahu SK, Dani A. Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study. The Journal of Indian Prosthodontic Society. 2025. doi:10.4103/jips.jips_8_24
BibTeX
@article{Jangade2025,
author = {Jangade, Manish and Sharma, Ranu and Sudharson, Nishanth A and Jain, Raj and Sahu, Shailendra Kumar and Dani, Anurag},
title = {Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study},
journal = {The Journal of Indian Prosthodontic Society},
year = {2025},
doi = {10.4103/jips.jips_8_24}
}