Evaluation of optical, surface, and microbiological properties of computer-aided design/computer-aided manufacturing-milled and three-dimensional-printed denture bases after aging by thermocycling: An in vitro study
The Journal of Indian Prosthodontic Society · 2025
DOI: 10.4103/jips.jips_88_25 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Indian Prosthodontic Society, 2025. Verfasst von Victor Augusto Alves Bento und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department Dental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil. Hauptthemen laut MEDLINE: Printing, Three-Dimensional, Candida albicans, Computer-Aided Design, Denture Bases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).
Abstract (Originalsprache)
Aim
The purpose of this study was to evaluate the surface properties, optical stability, and Candida albicans adhesion to resins used in the base of conventional, milled, and three-dimensional (3D)-printed dentures after aging by thermocycling. Settings and Design: In vitro study. Materials and Methods: A total of 96 resin samples were manufactured, divided into 3 resin groups ( n = 32) (conventional thermally activated, milled and 3D-printed), and subdivided into 4 aging times by thermocycling at temperatures 5 ± 1°C and 55 ± 1°C in 24h, 5.000, 10.000, 20.000 cycles ( n = 8), evaluating the adhesion of C. albicans , optical stability, surface roughness, hydrophilicity, and energy surface. Statistical Analysis Used: Data were evaluated by two-way ANOVA and Tukey’s test for pairwise comparisons ( P < .05).
Results
Conventional resin exhibited lower C. albicans colonization, with significant reductions at T1 (1.05±1.38) ( P = .003) and T3 (3.67 ±1.86) ( P = .023) compared to other resins. The conventional resin had significantly the lowest ΔE00 value at T0 (0.98 ± 0.41) ( P < .05). The milled resin had significantly lower roughness value at T0 (0.031 ± 0.00) ( P < .05). The conventional resin had significantly higher surface energy values compared to the other resins ( P < .05). The conventional resin exhibited a significantly lower water contact angle than the other resins ( P < .001).
Conclusion
The conventional thermally activated resin showed less adhesion of C. albicans than the resins manufactured by CAD/CAM. Among CAD/CAM resins, milled resin showed better properties than 3D-printed resin over time.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department Dental School, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil.
- Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, Sao Paulo, Brazil.
- Department Microbiology, Center for Biological and Health Sciences, Federal University of Mato Grosso do Sul, Campo Grande, MS, Brazil.
Zitieren
APA
Bento, V. A. A., Sayeg, J. M. C., Rosa, C. D. D. R. D., Lopes, L. F. T. P., Marques, M. C. S., & Pellizzer, E. P. (2025). Evaluation of optical, surface, and microbiological properties of computer-aided design/computer-aided manufacturing-milled and three-dimensional-printed denture bases after aging by thermocycling: An in vitro study. The Journal of Indian Prosthodontic Society. https://doi.org/10.4103/jips.jips_88_25
Vancouver
Bento VAA, Sayeg JMC, Rosa CDDRD, Lopes LFTP, Marques MCS, Pellizzer EP. Evaluation of optical, surface, and microbiological properties of computer-aided design/computer-aided manufacturing-milled and three-dimensional-printed denture bases after aging by thermocycling: An in vitro study. The Journal of Indian Prosthodontic Society. 2025. doi:10.4103/jips.jips_88_25
BibTeX
@article{Bento2025,
author = {Bento, Victor Augusto Alves and Sayeg, João Mateus Cavalaro and Rosa, Cleber Davi Del Rei Daltro and Lopes, Leonardo Ferreira de Toledo Piza and Marques, Maria Carolina Silva and Pellizzer, Eduardo Piza},
title = {Evaluation of optical, surface, and microbiological properties of computer-aided design/computer-aided manufacturing-milled and three-dimensional-printed denture bases after aging by thermocycling: An in vitro study},
journal = {The Journal of Indian Prosthodontic Society},
year = {2025},
doi = {10.4103/jips.jips_88_25}
}
EUVIMED