Novel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery
Journal of Craniovertebral Junction and Spine · 2026-07 · 17 (4) · 361-366
DOI: 10.4103/jcvjs.jcvjs_32_26 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Craniovertebral Junction and Spine, online erschienen am 24.07.2026. Verfasst von Abhishek Soni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Manipal Comprehensive Spine Care Center, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Background
Unsuccessful intraoperative computed tomography (CT) registration creates significant technical barriers limiting robot-assisted spine surgery implementation in obese populations due to imaging system field-of-view constraints exceeding patient dimensions. Materials and Methods: This consecutive series evaluated 63 patients with body mass index exceeding 40 kg/m 2 undergoing robot-assisted thoracolumbar fusion between October 2023 and November 2024. A lateral reference marker positioning strategy exploited O-arm’s asymmetric spatial coverage (40 cm transverse vs. 15 cm anteroposterior). Systematic preliminary radiographic assessment guided positioning selection, with lateral placement implemented when scout images demonstrated inadequate fiducial visualization or when patient dimensions approached field-of-view limitations.
Results
Lateral positioning was implemented in 17 (27.0%) cases. This approach eliminated severe registration failures, with zero patients requiring more than one reattempt compared to 3 (6.5%) patients in the standard positioning cohort requiring two or more reattempts. Ultimate registration success reached 100% across all cases. First-attempt success was achieved in 82.5% of procedures. Patients requiring reattempts demonstrated significantly prolonged O-arm acquisition intervals (30.3 vs. 19.4 min, P = 0.003) and elevated radiation exposure (61.6 vs. 38.3 mGy, P < 0.001). Optimal pedicle screw positioning (Gertzbein–Robbins Grade A + B) was maintained regardless of technique (lateral 97.6% vs. standard 96.9%, P = 0.650).
Conclusion
Lateral reference marker positioning resolves CT registration challenges in obese patients undergoing robot-assisted spine surgery, achieving universal success using existing equipment without additional capital investment.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Manipal Comprehensive Spine Care Center, Manipal Institute of Robotic Spine Surgery, Manipal Hospital, Bengaluru, Karnataka, India.
- Department of Orthopaedics, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, India.
- Department of Spine Anesthesia, Manipal Comprehensive Spine Care Center, Manipal Hospital, Bengaluru, Karnataka, India.
Zitieren
APA
Soni, A., Vidyadhara, S., Balamurugan, T., & Vidyadhara, A. (2026). Novel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery. Journal of Craniovertebral Junction and Spine, 17(4), 361-366. https://doi.org/10.4103/jcvjs.jcvjs_32_26
Vancouver
Soni A, Vidyadhara S, Balamurugan T, Vidyadhara A. Novel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery. Journal of Craniovertebral Junction and Spine. 2026;17(4):361-366. doi:10.4103/jcvjs.jcvjs_32_26
BibTeX
@article{Soni2026,
author = {Soni, Abhishek and Vidyadhara, S and Balamurugan, T and Vidyadhara, Alia},
title = {Novel lateral fiducial marker positioning technique eliminates registration failures in high-body mass index patients during robot-assisted spine surgery},
journal = {Journal of Craniovertebral Junction and Spine},
year = {2026},
volume = {17},
number = {4},
pages = {361--366},
doi = {10.4103/jcvjs.jcvjs_32_26}
}
EUVIMED