Robot-assisted pedicle screw navigation using two-step surface registration
Results in Engineering · 2026-12 · 32 · 113156
DOI: 10.1016/j.rineng.2026.113156 ↗Kurz gefasst
Fachartikel in der Zeitschrift Results in Engineering, 2026-12. Verfasst von Krittanat Tanthuvanit und 2 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Mahidol University.
Abstract (Originalsprache)
Robot-assisted pedicle screw navigation requires accurate registration between preoperative CT-based planning data and intraoperative anatomy, but surface-registration workflows can be time-consuming and may require repeated imaging. This phantom study aimed to validate a rapid two-step surface-registration pipeline for a robot-assisted pedicle screw navigation workflow. The BART LAB Spine Surgical Robot integrates CT-based preoperative planning in 3D Slicer, optical tracking, and stylus-based surface acquisition. Coarse alignment using singular value decomposition (SVD) from three anatomical landmarks was refined using point-to-plane iterative closest point (ICP) registration with 200–1,000 vertebral surface points. Registration performance was evaluated in 75 independent trials on three 3D-printed lumbar phantoms using local target registration error (TRE), pose-level translational error, pose-level angular error, and elapsed registration time. The initial SVD alignment produced an FRE of 1.51 ± 0.50 mm, while post-ICP local TRE remained below 0.42 mm across all tested point-cloud densities. Pose-level translational and angular errors improved with increasing point density and reached 1.39 ± 0.46 mm and 0.93 ∘ ± 0.41 ∘ , respectively, at 800 points. The elapsed registration time increased approximately linearly from 32.6 ± 2.9 s at 200 points to 93.5 ± 4.1 s at 1,000 points. Approximately 800 sampled points represented a practical knee point in the speed–accuracy trade-off. These results support the feasibility of the registration component in a controlled phantom setting, while downstream screw-placement accuracy remains to be evaluated in cadaveric and clinical studies.
Förderung
- Mahidol University
Zitieren
APA
Tanthuvanit, K., Chumnanvej, S., & Suthakorn, J. (2026). Robot-assisted pedicle screw navigation using two-step surface registration. Results in Engineering, 32, 113156. https://doi.org/10.1016/j.rineng.2026.113156
Vancouver
Tanthuvanit K, Chumnanvej S, Suthakorn J. Robot-assisted pedicle screw navigation using two-step surface registration. Results in Engineering. 2026;32:113156. doi:10.1016/j.rineng.2026.113156
BibTeX
@article{Tanthuvanit2026,
author = {Tanthuvanit, Krittanat and Chumnanvej, Sorayouth and Suthakorn, Jackrit},
title = {Robot-assisted pedicle screw navigation using two-step surface registration},
journal = {Results in Engineering},
year = {2026},
volume = {32},
pages = {113156},
doi = {10.1016/j.rineng.2026.113156}
}
EUVIMED