EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Prospective assessment of a wavefront-based refraction module in a multimodal diagnostic device compared to subjective refraction

Kabbinale Ranjitha, Sonam Kumar, Jyoti Damani, Mithesh Yadav, Harsh Rastogi, Anshul Chauhan, Shubhi Singh, Divya Parthasarathy Rao, Mona Duggal, Kalpa Negiloni

Journal of Clinical Ophthalmology and Research · 2026-10 · 14 (4) · 423-429

DOI: 10.4103/jcor.jcor_42_26 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clinical Ophthalmology and Research, online erschienen am 18.11.2026. Verfasst von Kabbinale Ranjitha und 9 weiteren Autor:innen. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Accurate and efficient refractive assessment is increasingly important in modern clinical practice, where dependence on skilled personnel and time-consuming techniques may limit workflow efficiency. This study evaluated the accuracy and efficiency of the refraction module of Pristine VX650 in comparison with retinoscopy and subjective refraction. Materials and Methods: This prospective cross-sectional study enrolled 143 subjects undergoing pre-LASIK evaluation, with a mean age of 27.84 ± 7.18 years. Refractive measurements were obtained using VX650 under photopic and scotopic conditions, retinoscopy, and noncycloplegic subjective refraction. Vector analysis was performed to calculate spherical equivalent (M) and astigmatic components (J0 and J45). Agreement was assessed using Bland–Altman analysis. Repeatability was evaluated in 50 subjects using intraclass correlation coefficients (ICCs), and measurement time was assessed in 25 subjects.

Results

VX650 showed strong correlation with subjective refraction for M and J0 under both scotopic and photopic conditions, with r values of 0.96 and 0.97 for M and 0.80 and 0.87 for J0, respectively. Mean differences in M compared with retinoscopy were 0.00 D in photopic and −0.01 D in scotopic conditions. Agreement within ±0.50 D was 82.52% and 79.02% for M, respectively, and exceeded 90% for astigmatic components. VX650 demonstrated excellent repeatability, with ICC of 0.99, and was significantly faster than retinoscopy.

Conclusion

In noncycloplegic, pre-LASIK adults, the wavefront-based VX650 module provided repeatable refractive measurements with good agreement against retinoscopy and reasonable agreement with subjective refraction, while reducing measurement time. Agreement with subjective refraction was lower in higher myopes, indicating that subjective refinement remains necessary in such cases.

Zitieren

APA

Ranjitha, K., Kumar, S., Damani, J., Yadav, M., Rastogi, H., Chauhan, A., Singh, S., Rao, D. P., Duggal, M., & Negiloni, K. (2026). Prospective assessment of a wavefront-based refraction module in a multimodal diagnostic device compared to subjective refraction. Journal of Clinical Ophthalmology and Research, 14(4), 423-429. https://doi.org/10.4103/jcor.jcor_42_26

Vancouver

Ranjitha K, Kumar S, Damani J, Yadav M, Rastogi H, Chauhan A, et al. Prospective assessment of a wavefront-based refraction module in a multimodal diagnostic device compared to subjective refraction. Journal of Clinical Ophthalmology and Research. 2026;14(4):423-429. doi:10.4103/jcor.jcor_42_26

BibTeX
@article{Ranjitha2026,
  author = {Ranjitha, Kabbinale and Kumar, Sonam and Damani, Jyoti and Yadav, Mithesh and Rastogi, Harsh and Chauhan, Anshul and Singh, Shubhi and Rao, Divya Parthasarathy and Duggal, Mona and Negiloni, Kalpa},
  title = {Prospective assessment of a wavefront-based refraction module in a multimodal diagnostic device compared to subjective refraction},
  journal = {Journal of Clinical Ophthalmology and Research},
  year = {2026},
  volume = {14},
  number = {4},
  pages = {423--429},
  doi = {10.4103/jcor.jcor_42_26}
}
Kostenlos starten →