Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis
Frontiers in Digital Health · 17.11.2026 · 8
DOI: 10.3389/fdgth.2026.1920169 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Digital Health, online erschienen am 17.11.2026. Verfasst von Yi Zhen und 3 weiteren Autor:innen. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Künstliche Intelligenz in der Pflege, Simulation in der Pflegeausbildung
Abstract (Originalsprache)
Introduction
Personalized optical simulation and machine learning provide a computational approach to estimating spectacle prescriptions for pediatric astigmatism.
Methods
This single-center, prospective, within-subject agreement study with randomized examination order evaluated prescriptions for 77 right eyes at a post-cycloplegia follow-up visit. The model used structured numerical wavefront exports and patient information for individualized optical reconstruction, virtual lens simulation, and clinical prescription residual calibration, and was developed using a separate dataset of 5,630 eyes. Artificial intelligence (AI) estimates and conventional autorefraction were compared with subjective refraction performed by an experienced optometrist masked to AI outputs. Children and the trial-lens outcome assessor were masked to prescription source, and lens presentation order was randomized. Agreement was evaluated for spherical equivalent (SE), J0, and J45. Inferential analyses were exploratory, without adjustment for multiple comparisons.
Results
SE mean bias ± standard deviation of paired differences was 0.01 ± 0.48 D for AI and 0.22 ± 0.57 D for conventional autorefraction; conventional Bland-Altman limits of agreement were −0.94 to 0.96 D and −0.89 to 1.33 D, respectively. The between-method difference in signed bias was −0.21 D (95% confidence interval: −0.35 to −0.07; P = 0.004). SE mean absolute errors were 0.30 D and 0.39 D, with a paired difference of −0.09 D (95% bootstrap confidence interval: −0.23 to 0.04). Astigmatic error analyses did not establish an overall advantage for AI. In the immediate comparison, trial-lens logMAR visual acuity was lower with AI, and 66.2% of participants preferred the AI prescription.
Discussion
A smaller SE mean bias does not establish greater individual accuracy, clinical interchangeability, or the effectiveness of AI-assisted clinical decision-making. Long-term benefits and safety during spectacle wear require further evaluation.
Zitieren
APA
Zhen, Y., Chang, H., Huang, Y., & Gao, J. (2026). Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis. Frontiers in Digital Health, 8. https://doi.org/10.3389/fdgth.2026.1920169
Vancouver
Zhen Y, Chang H, Huang Y, Gao J. Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis. Frontiers in Digital Health. 2026;8. doi:10.3389/fdgth.2026.1920169
BibTeX
@article{Zhen2026,
author = {Zhen, Yi and Chang, Hong and Huang, Yan and Gao, Jie},
title = {Wavefront-based optical simulation and machine learning for pediatric astigmatic refraction: a prospective agreement study using power vector analysis},
journal = {Frontiers in Digital Health},
year = {2026},
volume = {8},
doi = {10.3389/fdgth.2026.1920169}
}
EUVIMED