EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-SA 4.0

One-year Impact of Clinical and Echocardiographic Parameters in Cardiac Implantable Electronic Device Infection after Transvenous Extraction

Sara Hana Weisz, Chiara Sordelli, Nunzia Fele, Angela Guarino, Raffaele Verde, Giulio Zucchelli, Corrado Severino, Vittorio Attanasio, Stefano De Vivo, Carlo Tascini, Sergio Severino

Journal of Cardiovascular Echography · 2024-10 · 34 (4) · 196-202

DOI: 10.4103/jcecho.jcecho_55_24 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Cardiovascular Echography, online erschienen am 19.12.2024. Verfasst von Sara Hana Weisz und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine and Cardiology, Cardiology Unit, AO dei Colli - Cotugno Hospital, Napoli, Italy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Cardiac implantable electronic device infection (CIEDi) represents a serious complication with a poor prognosis. Many studies have underlined the importance of comorbidities on prognosis, but less is known about the impact of echocardiographic parameters. The aim of our study was to evaluate the clinical and echocardiographic characteristics of patients hospitalized for CIEDi submitted to transvenous extraction and their impact on 1-year follow-up. Materials and Methods: This is a retrospective cohort study that evaluated patients hospitalized for CIEDi in 2019 in two high-volume centers (Cotugno Hospital of Napoli and University Hospital of Pisa).

Results

Sixty-eight patients (72 ± 12 years, 24% females) were included. Isolated pocket infection was present in 30 patients (44%), whereas systemic infection in 38 (56%). In 24 patients (35%), it was possible to identify responsible germ, with a higher prevalence of Staphylococcus epidermidis (24%) and Staphylococcus aureus (16%). The mean ejection fraction (EF) was 45 ± 14%, 44% of patients had one vegetation (11.0 ± 8.0 mm), and 19% had multiple. Transthoracic echocardiography (TTE) failed to identify vegetation in 16 patients, whereas transesophageal echocardiography (TEE) was diagnostic. All patients underwent transvenous extraction of infected devices. After the procedure, echocardiographic ghosts were found in six patients (9%). At 1-year follow-up, all-cause mortality was 16%, mortality for cardiovascular cause was 12%, and no reinfection was recorded. Patients with EF ≤40% showed a significantly higher incidence of all-cause mortality (32% vs. 5%, P = 0.003) and mortality for cardiovascular causes (25% vs. 3%, P = 0.005). At adjusted Cox regression model, reduced EF ≤40% (adjusted hazard ratio [AdjHR] = 9.887, confidence interval [CI] =1.782–54.863; P = 0.009) and diabetes (AdjHR = 5.687, CI = 1.243–26.011; P = 0.025) were strong independent predictors of all-cause mortality. Moreover, reduced EF ≤40% (AdjHR = 17.382, CI = 1.379–219.037; P = 0.027), the presence of ghost (AdjHR = 14.584, CI = 1.465–145.197; P = 0.022), and diabetes (AdjHR = 11.334, CI = 1.506–85.315; P = 0.018) were strong independent predictors of mortality for cardiovascular cause.

Conclusions

Echocardiography (TTE and TEE) is a fundamental tool for the diagnosis and follow-up of CIEDi. In our population, diabetes mellitus and echocardiographic-derived parameters as reduced EF ≤40% and the presence of ghosts were strongly associated with 1-year mortality.

Schlagwörter

Stichwörter der Autor:innen

Cardiac implantable electronic device infectiondiabetes mellitusendocarditisghostprognosisreduced ejection fraction

Autor:innen und Institutionen

  • Department of Medicine and Cardiology, Cardiology Unit, AO dei Colli - Cotugno Hospital, Napoli, Italy.
  • Department of Cardiac-Thoracic and Vascular, Second Division of Cardiology, University Hospital of Pisa, Pisa, Italy.
  • First Division of Infectious Diseases, Cotugno Hospital, AORN dei Colli, Napoli, Italy.
  • Department of Medicine and Cardiology, Cardiology Unit, AO dei Colli - Monaldi Hospital, Napoli, Italy.
  • Department of Medicine (DAME), Infectious Diseases Clinic, University of Udine, Udine, Italy.
  • Infectious Diseases Clinic, Azienda Sanitaria Universitaria Del Friuli Centrale, Udine, Italy.

Zitieren

APA

Weisz, S. H., Sordelli, C., Fele, N., Guarino, A., Verde, R., Zucchelli, G., Severino, C., Attanasio, V., De Vivo, S., Tascini, C., & Severino, S. (2024). One-year Impact of Clinical and Echocardiographic Parameters in Cardiac Implantable Electronic Device Infection after Transvenous Extraction. Journal of Cardiovascular Echography, 34(4), 196-202. https://doi.org/10.4103/jcecho.jcecho_55_24

Vancouver

Weisz SH, Sordelli C, Fele N, Guarino A, Verde R, Zucchelli G, et al. One-year Impact of Clinical and Echocardiographic Parameters in Cardiac Implantable Electronic Device Infection after Transvenous Extraction. Journal of Cardiovascular Echography. 2024;34(4):196-202. doi:10.4103/jcecho.jcecho_55_24

BibTeX
@article{Weisz2024,
  author = {Weisz, Sara Hana and Sordelli, Chiara and Fele, Nunzia and Guarino, Angela and Verde, Raffaele and Zucchelli, Giulio and Severino, Corrado and Attanasio, Vittorio and De Vivo, Stefano and Tascini, Carlo and Severino, Sergio},
  title = {One-year Impact of Clinical and Echocardiographic Parameters in Cardiac Implantable Electronic Device Infection after Transvenous Extraction},
  journal = {Journal of Cardiovascular Echography},
  year = {2024},
  volume = {34},
  number = {4},
  pages = {196--202},
  doi = {10.4103/jcecho.jcecho_55_24}
}