Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 10.09.2024. Verfasst von Rajesh Sinha und 8 weiteren Autor:innen. Beteiligte Einrichtung: Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Visual Acuity, Refraction, Ocular, Phakic Intraocular Lenses, Corneal Stroma. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-SA 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the visual outcomes of implantable Collamer lens (ICL) with small incision lenticule extraction (SMILE) in cases of moderate-high myopia.

Methods

A prospective comparative study was conducted on 60 eyes of 30 patients with moderate-high myopia (−3D to −8D with astigmatism ≤1 D) at a tertiary eye care center. Patients underwent either SMILE or ICL in both eyes and had a postoperative follow-up of 1 year.

Results

The manifest refractive spherical equivalent was −5.22 ± 1.05 D and −5.4 ± 1.17 D in the SMILE and ICL groups, respectively ( P = 0.53). The mean sphere and cylinder were comparable between the groups. The mean uncorrected visual acuity improved from 1.18 ± 0.19 logMAR to 0.03 ± 0.07 logMAR in SMILE and 1.14 ± 0.25 logMAR to 0.011 ± 0.04 logMAR in the ICL group. The efficacy for SMILE was 83.3% and that for ICL was 93.3%. Safety and predictability (±0.5D) for both was 100%. A significant increase was observed in ocular aberration with a decrease in modular transfer function in the eyes that underwent SMILE, whereas no significant change in the eyes that underwent ICL. A significant difference was observed in all parameters of ocular aberration except corneal trefoil, corneal astigmatism, and PSF between the two groups at the final follow-up. The contrast sensitivity at final follow-up was higher in ICL cases when compared to SMILE. The quality of vision (QoV) score suggested a better QoV with ICL; however, the difference was not statistically significant.

Conclusion

Both SMILE and ICL are safe in patients with moderate-high myopia. The efficacy, contrast sensitivity, and postoperative ocular aberration profile are better in cases undergoing ICL.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual AcuityRefraction, OcularPhakic Intraocular LensesCorneal StromaHumansPilot ProjectsProspective StudiesMaleFemaleAdultYoung AdultFollow-Up StudiesTreatment OutcomeLens Implantation, IntraocularMyopia, DegenerativeMyopiaMicrosurgeryCorneal Surgery, Laser

Autor:innen und Institutionen

  • Dr. Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.
  • Department of Ophthalmology, LVPEI, Hyderabad, Telangana, India.
  • Guru Nanak Eye Centre, Maulana Azad Medical College, New Delhi, India.

Zitieren

APA

Sinha, R., Daga, J., Sahay, P., Gupta, V., Agarwal, T., Sharma, N., Maharana, P. K., Khokhar, S. K., & Titiyal, J. S. (2025). Visual outcomes with implantable Collamer lens versus small incision lenticule extraction in moderate-high myopia: A pilot study. Indian Journal of Ophthalmology, 73(1), 115-121. https://doi.org/10.4103/ijo.ijo_908_24

Vancouver

Sinha R, Daga J, Sahay P, Gupta V, Agarwal T, Sharma N, et al. Visual outcomes with implantable Collamer lens versus small incision lenticule extraction in moderate-high myopia: A pilot study. Indian Journal of Ophthalmology. 2025;73(1):115-121. doi:10.4103/ijo.ijo_908_24

BibTeX
@article{Sinha2025,
  author = {Sinha, Rajesh and Daga, Juhi and Sahay, Pranita and Gupta, Vinay and Agarwal, Tushar and Sharma, Namrata and Maharana, Prafulla K and Khokhar, Sudarshan K and Titiyal, Jeewan S},
  title = {Visual outcomes with implantable Collamer lens versus small incision lenticule extraction in moderate-high myopia: A pilot study},
  journal = {Indian Journal of Ophthalmology},
  year = {2025},
  volume = {73},
  number = {1},
  pages = {115--121},
  doi = {10.4103/ijo.ijo_908_24}
}
Kostenlos starten →