Posterior capsular opacification and Nd:YAG capsulotomy rates in patients implanted with square-edged and non-square-edged intraocular lenses in manual small-incision cataract surgery: A randomized controlled study
Indian Journal of Ophthalmology · 2023
DOI: 10.4103/ijo.ijo_359_23 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Rajesh S Joshi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Government Medical College, Nagpur, Maharashtra, India. Hauptthemen laut MEDLINE: Cataract Extraction, Lenses, Intraocular, Surgical Wound, Cataract. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
To study posterior capsular opacification (PCO) and neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomy rates in patients implanted with square-edged and non-square-edged intraocular lenses (IOLs) in manual small-incision cataract surgery (MSICS).
Setting
Tertiary eye care center.
Design
Prospective, comparative, and randomized controlled study.
Methods
This study included patients with senile cataracts scheduled for MSICS and IOL implantation. One eye of each patient was randomized to the implantation of square-edged (S group) or non-square-edged IOL (NSQ group). An independent observer analyzed PCO at 6, 12, 18, and 24 months under slit-lamp illumination.
Results
A total of 104 eyes were included in this study. The mean age of the participants in the two groups was 63.2 (±8.2) years, and there were 65 (62.5%) men and 39 women (37.5%). The mean best-corrected visual acuity (BCVA) values at 6, 12, and 18 months were 0.157 (±0.10), 0.11 (±0.12), and 0.12 (±0.11), respectively, in the S group and 0.17 (±0.10), 0.17 (±0.12), and 0.20 (±0.17), respectively, in the NSQ group. At 12 ( P = 0.03) and 18 months ( P = 0.01) follow-up, the BCVA of the S group was significantly better than that of the NSQ group. Four eyes in the NSQ group and one eye in the S group required Nd: YAG.
Conclusion
Evaluation of PCO and Nd:YAG capsulotomy rates showed that the 360° square of the posterior IOL edge plays a role in the prevention of PCO. Owing to the low cost of the material and the easy availability of IOLs manufactured from it, square-edged IOL has a definite role in the prevention of PCO in MSICS.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ophthalmology, Government Medical College, Nagpur, Maharashtra, India.
Zitieren
APA
Joshi, R. S., & Rasal, A. V. (2023). Posterior capsular opacification and Nd:YAG capsulotomy rates in patients implanted with square-edged and non-square-edged intraocular lenses in manual small-incision cataract surgery: A randomized controlled study. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_359_23
Vancouver
Joshi RS, Rasal AV. Posterior capsular opacification and Nd:YAG capsulotomy rates in patients implanted with square-edged and non-square-edged intraocular lenses in manual small-incision cataract surgery: A randomized controlled study. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_359_23
BibTeX
@article{Joshi2023,
author = {Joshi, Rajesh S and Rasal, Ashwini V},
title = {Posterior capsular opacification and Nd:YAG capsulotomy rates in patients implanted with square-edged and non-square-edged intraocular lenses in manual small-incision cataract surgery: A randomized controlled study},
journal = {Indian Journal of Ophthalmology},
year = {2023},
doi = {10.4103/ijo.ijo_359_23}
}
EUVIMED