EUVIMEDEUVIMED entdecken
KommentarOpen Access

Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism

Tianru Jin, Lan Yu, Jingjing Li, Yanwen Zhou

Indian Journal of Ophthalmology · 2023-08 · 71 (8) · 2967-2971

DOI: 10.4103/ijo.ijo_3385_22 ↗

Kurz gefasst

Kommentar in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 01.08.2023. Verfasst von Tianru Jin und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cataract Surgery, Shenyang Aier Eye Optometry Hospital, Shenyang, China. Hauptthemen laut MEDLINE: Astigmatism, Phacoemulsification, Lenses, Intraocular, Corneal Diseases. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate whether the toric intra-ocular lens (IOL) power calculation based on total corneal astigmatism (TCA) in eyes with high posterior corneal astigmatism (PCA) could result in a systematic over-correction or under-correction after operation.

Methods

The present study included a mono-centric retrospective study design. The data were collected from 62 consecutive eyes during uncomplicated cataract surgery by a single surgeon with a measured PCA of 0.50 diopters (D) or higher. Toric IOL calculations were made using TCA measurements. The eyes were grouped as either “with-the-rule” (WTR) or “against-the-rule” (ATR) on the basis of the steep anterior corneal meridian. The post-operative refractive astigmatic prediction error was analyzed 1 month post-operatively using the vector analysis by the Alpins method and double-angle plots method.

Results

The correction indexes were 1.14 ± 0.29 in the ATR eyes and 1.25 ± 0.18 for the WTR eyes, indicating a tendency toward over-correction. The mean over-correction was 0.22 ± 0.52D in the ATR group and 0.65 ± 0.60D in the WTR group. The magnitude of error (ME) values were significantly different from the ideal value of zero in both groups (ATR: P = 0.03; WTR: P = 0.00). No significant difference in mean absolute error (MAE) in predicted residual astigmatism was found between ATR and WTR groups (0.61 ± 0.42 D versus 0.64 ± 0.39 D; P = 0.54). The ATR group yielded better results, with 48%

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismPhacoemulsificationLenses, IntraocularCorneal DiseasesHumansLens Implantation, IntraocularRetrospective StudiesCorneal TopographyRefraction, Ocular

Stichwörter der Autor:innen

Posterior corneal astigmatismrefractive surgerytoric IOLtotal corneal astigmatism

Autor:innen und Institutionen

  • Department of Cataract Surgery, Shenyang Aier Eye Optometry Hospital, Shenyang, China.

Zitieren

APA

Jin, T., Yu, L., Li, J., & Zhou, Y. (2023). Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism. Indian Journal of Ophthalmology, 71(8), 2967-2971. https://doi.org/10.4103/ijo.ijo_3385_22

Vancouver

Jin T, Yu L, Li J, Zhou Y. Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism. Indian Journal of Ophthalmology. 2023;71(8):2967-2971. doi:10.4103/ijo.ijo_3385_22

BibTeX
@article{Jin2023,
  author = {Jin, Tianru and Yu, Lan and Li, Jingjing and Zhou, Yanwen},
  title = {Refractive outcomes of toric intra-ocular lens implantation in cases of high posterior corneal astigmatism},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  volume = {71},
  number = {8},
  pages = {2967--2971},
  doi = {10.4103/ijo.ijo_3385_22}
}
Kostenlos starten →