Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Zhi Yang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cataract, Shenyang Aier Eye Optometry Hospital, Shenyang, China. Hauptthemen laut MEDLINE: Astigmatism, Phacoemulsification, Lenses, Intraocular. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate a method using measured values of total corneal refractive power (TCRP) for a manufacturer’s online calculator by comparing it with the Barrett toric calculator (BTC) and Kane toric calculator (KTC) combined with simulated keratometry values (SimK).

Methods

This was a retrospective case series. Patient records were reviewed to identify the patients who had biometry with the IOL Master 700 and Pentacam recorded before toric IOL implantation and refractive follow-up data after implantation. The predicted error in residual astigmatism was calculated by vector analysis according to the calculation methods and the measurements used.

Results

A total of 70 eyes of 56 patients were included. The mean absolute astigmatism prediction errors were 0.6 ± 0.32, 0.59 ± 0.35, and 0.61 ± 0.35 D for the ATC TCRP , BTC SimK , and KTC SimK calculators, respectively ( P = 0.934), and the centroid of the prediction errors were 0.3 D @ 178°, 0.11 D @ 102°, and 0.09 D @ 147°, respectively ( P = 0.23). In the with-the-rule subgroup, the centroid of the prediction error was 0.34 D @ 176° for ATC TCRP and was the highest among the three calculation methods ( P = 0.046).

Conclusion

The ATC TCRP , BTC SimK , and KTC SimK calculators had similar performance with regards to their astigmatism prediction accuracy. The ATC TCRP calculator combined with 4.0-mm apex/ring readings of TCRP was slightly intended to result in against-the-rule residual astigmatism.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AstigmatismPhacoemulsificationLenses, IntraocularHumansLens Implantation, IntraocularVisual AcuityRetrospective StudiesCorneal TopographyCorneaRefraction, Ocular

Stichwörter der Autor:innen

AstigmatismBarrettKanecalculationcataracttotal corneal refractive power

Autor:innen und Institutionen

  • Department of Cataract, Shenyang Aier Eye Optometry Hospital, Shenyang, China.

Zitieren

APA

Yang, Z., Zhou, Y., Jin, T., & Li, J. (2023). An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_1539_22

Vancouver

Yang Z, Zhou Y, Jin T, Li J. An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_1539_22

BibTeX
@article{Yang2023,
  author = {Yang, Zhi and Zhou, Yanwen and Jin, Tianru and Li, Jingjing},
  title = {An evaluation of the accuracy of toric intraocular lens power calculation based on measured total corneal refractive power},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_1539_22}
}