EUVIMEDEUVIMED entdecken
Open Access

Universal slit-lamp mounted indentation gonioscopy tool for angle evaluation: An innovative device

Atul Bhirud, Anchal Tripathi, Mohini Agarwal, Avinash Mishra

Indian Journal of Ophthalmology · 2024

DOI: 10.4103/ijo.ijo_3035_23 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Atul Bhirud und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Military Hospital, Jalandhar, Punjab, India. Hauptthemen laut MEDLINE: Gonioscopy, Intraocular Pressure, Equipment Design, Glaucoma, Angle-Closure. Die Arbeit nennt 5 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the field of ophthalmology, slit-lamp gonioscopy has long been a cornerstone for examining anterior chamber angles and diagnosing conditions such as angle closure, secondary causes of raised intraocular pressure, neovascularization of angle, angle recession, angle tumors, and foreign bodies. However, the conventional approach for goniophotography is a demanding procedure requiring juggling a gonioscopy lens in one hand and a smartphone in the other. Balancing a gonioscopy lens with one hand makes it difficult to adjust and focus the image in busy clinical settings. This article introduces a groundbreaking solution to this problem – a universal slit-lamp–mounted gonioscope ingeniously repurposed from discarded materials, that is, indirect goniophotography (IndiGo). This novel system simplifies the process of both gonioscopy and goniophotography, allowing ophthalmologists to easily assess anterior chamber angles and capture high-quality images. These images can be swiftly shared with glaucoma specialists worldwide for digital analysis. Not only does this approach enhance examination efficiency, but also it fosters sustainability in ophthalmic diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

GonioscopyIntraocular PressureEquipment DesignGlaucoma, Angle-ClosureHumansAnterior ChamberSlit LampSlit Lamp Microscopy

Autor:innen und Institutionen

  • Department of Ophthalmology, Military Hospital, Jalandhar, Punjab, India.
  • Department of Ophthalmology, Military Hospital, Jammu, J&K, India.

Zitieren

APA

Bhirud, A., Tripathi, A., Agarwal, M., & Mishra, A. (2024). Universal slit-lamp mounted indentation gonioscopy tool for angle evaluation: An innovative device. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_3035_23

Vancouver

Bhirud A, Tripathi A, Agarwal M, Mishra A. Universal slit-lamp mounted indentation gonioscopy tool for angle evaluation: An innovative device. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_3035_23

BibTeX
@article{Bhirud2024,
  author = {Bhirud, Atul and Tripathi, Anchal and Agarwal, Mohini and Mishra, Avinash},
  title = {Universal slit-lamp mounted indentation gonioscopy tool for angle evaluation: An innovative device},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  doi = {10.4103/ijo.ijo_3035_23}
}
Kostenlos starten →