EUVIMEDEUVIMED entdecken
BeobachtungsstudieVergleichsstudieOpen Access · CC BY-NC-ND 4.0

Concordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer

Karthikesh Anche, Nikhil S Choudhari, Raghava Chary, Syed Haseeb, Sirisha Senthil

Indian Journal of Ophthalmology · 2025

DOI: 10.4103/ijo.ijo_2743_24 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Indian Journal of Ophthalmology, 2025. Verfasst von Karthikesh Anche und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department for Technology and Innovation, Center for Innovation and Technology, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Banjara Hills…. Hauptthemen laut MEDLINE: Intraocular Pressure, Tonometry, Ocular, Slit Lamp, Glaucoma. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 12 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate a new device, the Goldmann applanation tonometer (GAT) mounted on a novel handheld 3D-printed modular slit lamp (MSL), and compare it with the gold standard slit-lamp-mounted GAT and the handheld Perkins tonometer.

Methods

One hundred eyes from 100 participants were included in this cross-sectional observational study. The MSL mount was customized for the selected tonometer (Model AT030, Carl Zeiss, India). A Samsung Galaxy S2 mobile phone was used for observing mires and photography during tonometry. One observer measured intraocular pressure (IOP) with slit-lamp GAT, and another observer measured with MSL GAT and Perkins tonometers. The tonometry sequence was slit-lamp GAT, MSL GAT, and Perkins tonometer, with a 5-minute interval between readings.

Results

The median age of participants was 56 years (range: 16–83). The median IOP by slit-lamp GAT was 15 mmHg (range: 9–41). Tonometers were compared in pairs: slit-lamp GAT and Perkins, slit-lamp GAT and MSL GAT, and Perkins and MSL GAT. The pairwise Spearman rank correlations were 0.988, 0.988, and 0.983 (all P < 0.001). The mean differences in IOP (95% limits of agreement) were 0.5 (-0.6 to 1.6), 1.2 (0 to 2.4), and 0.7 (-0.7 to 2.1) mmHg, respectively.

Conclusion

The MSL-mounted GAT provides reliable IOP readings with minor underestimation (within 2 mmHg in 88% of cases), suggesting its potential utility in clinical practice as a portable slit lamp and anterior segment imaging device.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Intraocular PressureTonometry, OcularSlit LampGlaucomaSlit Lamp MicroscopyHumansCross-Sectional StudiesMaleFemaleMiddle AgedAdultAgedAdolescentYoung AdultAged, 80 and overEquipment DesignReproducibility of Results

Stichwörter der Autor:innen

3D-printed tonometry modelGoldmann applanation tonometryglaucoma screeninghand-held tonometerintraocular pressuremodular slit lampportable tonometertonometry innovations

Autor:innen und Institutionen

  • Department for Technology and Innovation, Center for Innovation and Technology, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India.
  • Department of Glaucoma, VST Glaucoma Centre, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India.

Zitieren

APA

Anche, K., Choudhari, N. S., Chary, R., Haseeb, S., & Senthil, S. (2025). Concordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2743_24

Vancouver

Anche K, Choudhari NS, Chary R, Haseeb S, Senthil S. Concordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer. Indian Journal of Ophthalmology. 2025. doi:10.4103/ijo.ijo_2743_24

BibTeX
@article{Anche2025,
  author = {Anche, Karthikesh and Choudhari, Nikhil S and Chary, Raghava and Haseeb, Syed and Senthil, Sirisha},
  title = {Concordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer},
  journal = {Indian Journal of Ophthalmology},
  year = {2025},
  doi = {10.4103/ijo.ijo_2743_24}
}
Kostenlos starten →