Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2023. Verfasst von Neeraj Israni und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Innovision Eye Hospital and Laser Centre, Mumbai, Maharashtra, India. Hauptthemen laut MEDLINE: Lenses, Intraocular, Ophthalmology. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Toric Intraocular lenses (IOLs) are supposed to be aligned at a particular axis for spectacle-free vision for distance. The evolution of topographers and optical biometers has made it quite achievable for us to aim the target. However, the result sometimes remains unpredictable. A big aspect of this depends on the preop axis marking for toric IOL alignment. Errors in axis marking have been reduced recently with the array of different toric markers in the market, but still we see postoperative refractive surprises due to faulty marking.

Purpose

In this video, we present a novel slit lamp–based toric marker innovation, STORM, which gives us a hands-free approach to a reliable and accurate axis marking on the cornea. The axis marker is a simple modification to our age-old marker, with the advantage of no touch and slit-lamp assistance, which will make it error free and easy to use. Synopsis: The present innovation answers the problem statement of stable, economical, and accurate marking solution. Many a times, hand-holding devices create inaccurate and stressed condition while marking the cornea before corneal surgery. Highlights: The invention can be used for marking of accurate and easy astigmatic axis of a toric IOL preoperatively, that is, before the surgery. If the appropriate device is used to mark the cornea, it would impact the outcome of surgery. This device also makes the patient and the surgeon comfortable to mark the cornea with accuracy and without hesitation. Video link: https://youtu.be/4MVM7HRwz70 Key words: Slit lamp based toric marker, Corneal axis marker, Toric marker innovation- STORM

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularOphthalmologyHumansCorneaHydrogen PeroxideSlit Lamp

Stichwörter der Autor:innen

Corneal axis markerSlit lamp based toric markerToric marker innovation- STORM

Substanzen

Hydrogen Peroxide

Autor:innen und Institutionen

  • Department of Ophthalmology, Innovision Eye Hospital and Laser Centre, Mumbai, Maharashtra, India.
  • Department of Ophthalmology, CHL Hospital, Indore, Madhya Pradesh, India.
  • Department of Ophthalmology, Kantai Netralaya, Jalgaon, Maharashtra, India.
  • Department of Ophthalmology, Rushabh Eye Hospital, Mumbai, Maharashtra, India.

Zitieren

APA

Israni, N., Kochar, S., Kadu, A., & Shah, S. (2023). Slit-lamp assisted TORic Marker (STORM): A novel corneal axis marker. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_2779_22

Vancouver

Israni N, Kochar S, Kadu A, Shah S. Slit-lamp assisted TORic Marker (STORM): A novel corneal axis marker. Indian Journal of Ophthalmology. 2023. doi:10.4103/ijo.ijo_2779_22

BibTeX
@article{Israni2023,
  author = {Israni, Neeraj and Kochar, Shruti and Kadu, Amol and Shah, Shreya},
  title = {Slit-lamp assisted TORic Marker (STORM): A novel corneal axis marker},
  journal = {Indian Journal of Ophthalmology},
  year = {2023},
  doi = {10.4103/ijo.ijo_2779_22}
}
Kostenlos starten →