EUVIMEDEUVIMED entdecken
VergleichsstudieRandomisierte kontrollierte StudieOpen Access · CC BY-NC-ND 4.0

Evaluating the effects of trifocals and extended depth of focus intraocular lens implantation on stereopsis and contrast sensitivity in cataract patients

B V Pradeep, Priyanka R Pujari, Sheetal Madalagi, R Krishnaprasad

Indian Journal of Ophthalmology · 2026-05 · 74 (Suppl 1) · S23-S25

DOI: 10.4103/ijo.ijo_2015_25 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Indian Journal of Ophthalmology, online erschienen am 30.04.2026. Verfasst von B V Pradeep und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, M M Joshi Eye Institute, Hubli, Karnataka, India. Hauptthemen laut MEDLINE: Cataract, Contrast Sensitivity, Depth Perception, Lens Implantation, Intraocular. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the effects of trifocal and extended depth of focus (EDOF) intraocular lenses (IOLs) on stereopsis and contrast sensitivity following cataract surgery.

Method

This randomized, prospective, comparative study was conducted at the cataract department of a tertiary eye hospital. A total of 70 patients scheduled for cataract extraction were randomly assigned to two groups. Group 1 received AcrySof IQ PanOptix trifocal IOLs, while Group 2 received AcrySof IQ Vivity EDOF IOLs. Comprehensive evaluations were performed preoperatively and postoperatively at 1 week and 1 month.

Results

At 1 week postoperatively, both trifocal IOLs and EDOF IOLs demonstrated comparable outcomes in contrast sensitivity and stereopsis. At 1 month, stereopsis was significantly better in the EDOF group (89.14 ± 46.86 arc sec) than in the trifocal group (118.28 ± 44.81 arc sec; P = 0.017). Contrast sensitivity improved significantly in the EDOF group ( P = 0.023) but remained stable in the trifocal group. Intergroup contrast sensitivity differences were not statistically significant.

Conclusion

Both IOLs provided good stereopsis and contrast sensitivity in the early postoperative period. However, by 1 month, EDOF IOLs demonstrated significantly better stereopsis and improved contrast sensitivity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CataractContrast SensitivityDepth PerceptionLens Implantation, IntraocularMultifocal Intraocular LensesPhacoemulsificationVision, BinocularAgedFemaleHumansMaleMiddle AgedFollow-Up StudiesProspective StudiesProsthesis DesignVisual Acuity

Stichwörter der Autor:innen

CataractEDOF (extended depth of focus)contrast sensitivitystereopsistrifocal

Autor:innen und Institutionen

  • Department of Optometry, M M Joshi Eye Institute, Hubli, Karnataka, India.
  • Department of Ophthalmology, M M Joshi Eye Institute, Hubli, Karnataka, India.

Zitieren

APA

Pradeep, B. V., Pujari, P. R., Madalagi, S., & Krishnaprasad, R. (2026). Evaluating the effects of trifocals and extended depth of focus intraocular lens implantation on stereopsis and contrast sensitivity in cataract patients. Indian Journal of Ophthalmology, 74(Suppl 1), S23-S25. https://doi.org/10.4103/ijo.ijo_2015_25

Vancouver

Pradeep BV, Pujari PR, Madalagi S, Krishnaprasad R. Evaluating the effects of trifocals and extended depth of focus intraocular lens implantation on stereopsis and contrast sensitivity in cataract patients. Indian Journal of Ophthalmology. 2026;74(Suppl 1):S23-S25. doi:10.4103/ijo.ijo_2015_25

BibTeX
@article{Pradeep2026,
  author = {Pradeep, B V and Pujari, Priyanka R and Madalagi, Sheetal and Krishnaprasad, R},
  title = {Evaluating the effects of trifocals and extended depth of focus intraocular lens implantation on stereopsis and contrast sensitivity in cataract patients},
  journal = {Indian Journal of Ophthalmology},
  year = {2026},
  volume = {74},
  number = {Suppl 1},
  pages = {S23--S25},
  doi = {10.4103/ijo.ijo_2015_25}
}