Binocular visual function of Japanese eyes with nondiffractive extended depth-of-focus intraocular lenses made of high water-content hydrophobic acrylic material
Japanese Journal of Ophthalmology · 2026
DOI: 10.1007/s10384-025-01300-5 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Japanese Journal of Ophthalmology, 2026. Verfasst von Hisaharu Suzuki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Zengyo Suzuki Eye Clinic, Fujisawa, Japan. Hauptthemen laut MEDLINE: Vision, Binocular, Visual Acuity, Lenses, Intraocular, Acrylic Resins. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Alcon Japan.
Abstract (Originalsprache)
Purpose
To prospectively evaluate bilateral visual function in Japanese patients implanted with nondiffractive extended depth-of-focus (EDoF) intraocular lenses (IOLs). Study design Multisite prospective observational study. Patients and methods This study included 48 eyes of 24 Japanese patients with cataracts (mean age: 68.7 ± 9.2 years) who underwent bilateral implantation of nondiffractive EDoF IOLs CNAET0 (Clareon Vivity, Alcon), made of high-water-content hydrophobic acrylic material. Three months postoperatively, binocular uncorrected and distance-corrected visual acuities (BUCVA and BDCVA) were assessed at far, 66 cm, and 40 cm. Binocular photopic contrast sensitivity (CSV-1000), binocular defocus curves, spectacle independence, and photic phenomena (glare, halo, starburst, and waxy vision) were also assessed.
Results
The mean logMAR BUCVA/BDCVA was –0.11/–0.15 at far, 0.05/0.08 at 66 cm, and 0.18/0.22 at 40 cm. Binocular contrast sensitivity was within the normal range for individuals aged 60–69 years across all spatial frequencies. The mean defocus curve demonstrated 0.1 logMAR or better between −2.0 and +1.0 D addition, with better performance of 0.0 logMAR or better between −1.5 and +0.5 D addition. All patients were spectacle-independent for distance and intermediate vision, whereas nine of the 24 patients (37.5%) required spectacles for near vision. None of the patients reported severe photic phenomena; 17 patients (70.8%) did not experience glare or starburst, and 20 patients (83.3%) did not report halo or waxy vision.
Conclusion
Bilateral implantation of nondiffractive EDoF IOLs provided good binocular functional vision from far to near, although some patients may require spectacles for near vision. The photic phenomenon was minimal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Zengyo Suzuki Eye Clinic, Fujisawa, Japan.
- Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Kandamisaki-cho 2-9-18, Chiyoda-ku, Tokyo, 101-0061, Japan.
- Yokohama Sky Eye Clinic, Yokohama, Japan.
- Department of Ophthalmology, Tokyo Dental College Suidobashi Hospital, Kandamisaki-cho 2-9-18, Chiyoda-ku, Tokyo, 101-0061, Japan. bissen@tdc.ac.jp.
Förderung
- Alcon Japan
Zitieren
APA
Suzuki, H., Ota, Y., Hata, S., Minami, K., & Bissen-Miyajima, H. (2026). Binocular visual function of Japanese eyes with nondiffractive extended depth-of-focus intraocular lenses made of high water-content hydrophobic acrylic material. Japanese Journal of Ophthalmology. https://doi.org/10.1007/s10384-025-01300-5
Vancouver
Suzuki H, Ota Y, Hata S, Minami K, Bissen-Miyajima H. Binocular visual function of Japanese eyes with nondiffractive extended depth-of-focus intraocular lenses made of high water-content hydrophobic acrylic material. Japanese Journal of Ophthalmology. 2026. doi:10.1007/s10384-025-01300-5
BibTeX
@article{Suzuki2026,
author = {Suzuki, Hisaharu and Ota, Yuka and Hata, Seiichiro and Minami, Keiichiro and Bissen-Miyajima, Hiroko},
title = {Binocular visual function of Japanese eyes with nondiffractive extended depth-of-focus intraocular lenses made of high water-content hydrophobic acrylic material},
journal = {Japanese Journal of Ophthalmology},
year = {2026},
doi = {10.1007/s10384-025-01300-5}
}
EUVIMED