Fachartikel in der Zeitschrift Indian Journal of Ophthalmology, 2024. Verfasst von Rebika Dhiman und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India. Hauptthemen laut MEDLINE: Myopia, Refractive Errors, Keratomileusis, Laser In Situ. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To study the correlation of corneal topography, corneal biomechanical properties, and ocular aberrations with the magnitude of refractive error in myopic eyes.

Methods

All myopic patients attending the clinic for refractive surgery were recruited. Data recorded included visual acuity, axial length (AL), central corneal thickness (CCT), manifest refraction spherical equivalent (MRSE), topography (Pentacam – Oculus), corneal biomechanical factors [ocular response analyzer (ORA)], and optical aberrations (iTrace). They were further categorized into group 1 (suitable for femto-LASIK) and group 2 (unsuitable for femto-LASIK).

Results

Sixty eyes (30 myopes) of mean age 22.78 ± 2.71 years were enrolled. A negative correlation of refractive error was noted with AL (ρ = −0.9; P < 0.001), total aberrations (ρ = 0.53; P < 0.001), and lower-order aberrations (LOA) (ρ = 0.54; P < 0.001). A strongly positive correlation was noted between CCT and corneal hysteresis (CH) (ρ = 0.63; P < 0.001), CCT and CRF (ρ = 0.56; P < 0.001), CH and corneal resistance factor (CRF) (ρ = 0.83; P < 0.001), and Goldmann equivalent intraocular pressure (IOPg) and corneal compensated intraocular pressure (IOPcc) (ρ = 0.78; P < 0.001). An increase in higher-order aberrations (HOAs) as well as lower-order aberrations (LOAs) was noted with increasing sim-K [HOA (r = 0.73, P = 0.001); LOA (r = 0.601, P = 0.014)] and increasing CRF [HOA (r = 0.5, P = 0.006); LOA (r = 0.732, P = 0.001)] in group 2. The amount of refractive error, axial length, central corneal thickness, and sim-K were significantly different in the two groups.

Conclusion

Increasing degree of myopia is associated with an increase in axial length, total aberrations, and lower-order aberrations. Corneal biomechanical parameters have a strong correlation with each other. Lower corneal biomechanics are noted in high myopes as they have weaker and thinner corneas. Corneal biomechanics and ocular aberrations do not differ significantly between cases suitable for femto-LASIK and cases unsuitable for femto-LASIK.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MyopiaRefractive ErrorsKeratomileusis, Laser In SituHumansYoung AdultAdultCorneaIntraocular PressureBiomechanical Phenomena

Autor:innen und Institutionen

  • Dr. R. P. Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, India.

Zitieren

APA

Dhiman, R., Singh, D., Vanathi, M., Tandon, R., & Mahalingam, K. (2024). Biomechanical properties of cornea and ocular aberrations in myopic eyes. Indian Journal of Ophthalmology. https://doi.org/10.4103/ijo.ijo_1627_23

Vancouver

Dhiman R, Singh D, Vanathi M, Tandon R, Mahalingam K. Biomechanical properties of cornea and ocular aberrations in myopic eyes. Indian Journal of Ophthalmology. 2024. doi:10.4103/ijo.ijo_1627_23

BibTeX
@article{Dhiman2024,
  author = {Dhiman, Rebika and Singh, Divya and Vanathi, Murugesan and Tandon, Radhika and Mahalingam, Karthikeyan},
  title = {Biomechanical properties of cornea and ocular aberrations in myopic eyes},
  journal = {Indian Journal of Ophthalmology},
  year = {2024},
  doi = {10.4103/ijo.ijo_1627_23}
}
Kostenlos starten →