Fachartikel in der Zeitschrift Journal of the Pakistan Medical Association, 2025. Verfasst von Wafa Alotaibi und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia. Hauptthemen laut MEDLINE: Intraocular Pressure, Anterior Chamber, Cornea, Axial Length, Eye. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objectives
To evaluate axial length, anterior chamber angle, anterior chamber depth, refractive errors and white-to-white corneal diameter, and to assess their inter-correlations with intraocular pressure among young individuals.
Method
The prospective, cross-sectional study was conducted at the optometry clinics of King Saud University, Riyadh, Saudi Arabia, between January and April 2022, and comprised healthy subjects of either gender aged 8-37 years. Ocular parameters were noted, and the subjects were screened for ocular disorders with a slit lamp. The refractive error was assessed using an auto-refractometer. Data was analysed using SPSS 25.
Results
Of the 108 subjects, 61(56.5%) were females and 47(43.5%) were males. The overall mean age was 20.87±6.23 years. The mean anterior chamber angle was 39.26±5.04 degrees, mean anterior chamber depth was 3.06±0.30mm, mean white-to-white corneal diameter was 11.97±0.40mm, and mean intraocular pressure was 18.75±1.68mmHg. Intraocular pressure had a positive but non-significant correlation with myopia, anterior chamber angle, anterior chamber depth and axial length (p>0.05). Conversely, intraocular pressure had inverse but non-significant correlation with age, hyperopia and white-to-white corneal diameter (p>0.05).
Conclusion
Ocular biometric dimensions could be considered while assessing the risk factors for ocular hypertension. Key Words: Young adult, Clinical practice, Retina, Risk factors, Intraocular pressure.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Optometry, College of Applied Medical Sciences, King Saud University, Riyadh, Saudi Arabia.
- Department of Optometry, College of Applied Medical Sciences, Qassim University, Buraydah, Saudi Arabia.
Zitieren
APA
Alotaibi, W., & Alrasheed, S. (2025). Axial length, anterior chamber parameters, and white-to-white corneal diameter: Their inter-correlations with intraocular pressure among young Saudis. Journal of the Pakistan Medical Association. https://doi.org/10.47391/jpma.20964
Vancouver
Alotaibi W, Alrasheed S. Axial length, anterior chamber parameters, and white-to-white corneal diameter: Their inter-correlations with intraocular pressure among young Saudis. Journal of the Pakistan Medical Association. 2025. doi:10.47391/jpma.20964
BibTeX
@article{Alotaibi2025,
author = {Alotaibi, Wafa and Alrasheed, Saif},
title = {Axial length, anterior chamber parameters, and white-to-white corneal diameter: Their inter-correlations with intraocular pressure among young Saudis},
journal = {Journal of the Pakistan Medical Association},
year = {2025},
doi = {10.47391/jpma.20964}
}
EUVIMED